Rs-232 Speed Setting; Switch Input Feature; Single Or Multiple Systems - DKS 1834 PC Programmable Installation & Owner's Manual

Pc programmable telephone entry system
Table of Contents

Advertisement

3.2.5 RS-232 Speed Setting

The following programming sequence sets an optional faster RS-232 speed. This feature is available on Rev M boards or higher
and the Remote Account Manager Software, Version 6.3.b, must be used.
Factory setting = 0 (9600 baud rate)
TUV
TUV
JKL
JKL
1. Press
and enter your four-digit MASTER CODE
8 8
5 5
OPER
OPER
2. Enter
for 9600 baud rate or
0 0
OPER
OPER
3. Press
together to end this programming sequence (beeeeeep).
0 0

3.2.6 Switch Input Feature

The following programming sequence sets the switch input (main terminals #4 and #6) to either activate a relay(s) or call the
phone number programmed in directory code 0, 00, 000 or 0000. Refer to section 3.3.4 to determine which relay(s) will activate
when the switch input is activated. This feature is available on Rev K boards or higher.
Factory setting = 0 (switch input activates relay)
SP
SP
TUV
TUV
1. Press
and enter your four-digit MASTER CODE
1 1
8 8
The LCD display will read: KEY IN DIAL? 0=N 1=Y
SP
SP
2. Enter
for YES (the switch input will dial a phone number) or
1 1
press
(beep).
OPER
OPER
3. Press
together to end this programming sequence (beeeeeep).
0 0

3.2.7 Single or Multiple Systems

This program sequence sets the telephone entry system to operate as a single unit on the phone line, or to share the phone line
with other units. If multiple systems are sharing the same phone line, then each one must be set as a "multiple system" and
each must have a unique master code.
Factory setting = Single System.
OPER
OPER
GHI
GHI
1. Press
and enter your four-digit MASTER CODE
0 0
4 4
OPER
OPER
2. Press
(beep) for a single system, OR
0 0
OPER
OPER
3. Press
together to end this programming sequence (beeeeeep).
0 0
STOP!!
If the telephone entry system is to be programmed from a PC, NO other programming is required at the system
itself. Refer to the Remote Account Manager for Windows Software help screens for additional programming information.
Continue with the remaining sections in this chapter if the telephone entry system will be programmed by any other method. If
the factory setting matches your need, there is no reason to reprogram that section.
Remember that advanced features like relay hold open time zones, security levels, and elevator control functions can ONLY be
programmed from the Remote Account Manager Software. If any of these advanced features are being used, DO NOT proceed
with any other programming steps in this manual.
26
SP
SP
for 19200 baud rate, then press
1 1
SP
SP
(beep) for multiple systems.
1 1
? ?
? ?
? ?
? ?
(beep).
(beep).
? ?
? ?
? ?
? ?
(beep).
OPER
OPER
for NO (the switch input will activate the relay), then
0 0
? ?
? ?
? ?
? ?
(beep).
1834-065-B-10-14