Fitting The Glass Panel; Full Operating Checks - Valor 961 Installation And Owner's Manual

Inset live fuel effect gas fire incorporating the fireslide control fitted with one of the following fascia: aurora, solaris or lunar
Table of Contents

Advertisement

13. FITTING THE WINDOW FRAME ASSEMBLY
1. Locate the window mounting frame and
window assembly in place.
2. Secure in place using the six screws
removed previously.
14.1 Checking the control settings.
Please note:
When first turned on from cold, the flames will appear predominantly blue. It is
normal for condensation to form on the rear of the window assembly. The
condensation will disappear after a few minutes use.
When operating the fire for the first time, some vapours may be given off which
could set off smoke alarms in the vicinity. These vapours are quite normal with new
appliances. They are totally harmless and will disappear after a few hours use.
1. Refit the battery if previously removed.
2. Make sure the slider button is at the off position (At topmost position).
3. Slide the button to the bottom (ignition) position. Retain in this position to ignite the
pilot. The burner should ignite at its lowest setting within 4 seconds of the pilot
igniting. Keep at this position for a further 10 seconds to allow the pilot flame to
stabilise.
4. Release the button. The button should automatically spring up to the low heat
position. If the flames go out at this stage or when checking the rest of the setting
positions, try the full lighting sequence again. If the flames fail after two attempts,
©
Baxi Heating U.K. Limited 2008.
INSTALLER GUIDE

14. FULL OPERATING CHECKS

Figure 26. Window mounting frame and
window assembly removal