Under no circumstances is this fire to be converted to LPG. An LPG conversion kit
does not exist for this gas fire.
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Inlet Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot & Atmosphere Sensing Device
Aeration Setting
The appliance information label is located on the base of the fire underneath the
burner module.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below:
Model
961
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
The conversion of net efficiency to gross was achieved by multiplying the net
efficiency by the following conversion factor from Table E3 of SAP 2005, rounding
down to the nearest whole number.
Gas
Natural Gas
©
Baxi Heating U.K. Limited 2008.
INSTALLER GUIDE

3. APPLIANCE DATA

Gas
Ignition
20.0 ± 1.0mbar (8.0 ± 0.4in w.g.)
Copreci Ref. O.D.S 21500/166
Electronic (Battery 9V PP3)
Efficiency % (Gross)
Conversion factor from net to gross efficiency
Page 7
Natural (G20)
20mbar
5.00kW (17,060 Btu/h)
2.5kW (8,530 Btu/h)
8mm pipe
Cat 82 - 065
See section 17.1
80
0.901