Page 1
V A L O R C O S Y F L A M E ( M O D E L B R 6 2 3 ) & V A L O R S E C R E T ( M O D E L B R 4 2 7 &...
Page 2
Kingdom (GB) and the Republic of Ireland (IE) only. This Installer Guide gives sufficient details to enable the appliance to be installed and maintained. If further information is required, our Valor Advice Line will be pleased to help. Please telephone 0345 626341 (Local call rates apply)
INSTALLATION NOTES In your own interest and for safety, in the United Kingdom, it is the law that all gas appliances are installed by competent persons in accordance with the current edition of the Gas Safety (Installation & Use) Regulations and Amendments. Failure to install the appliance correctly could lead to prosecution.
The A.S.D will shut the appliance down if an unacceptable amount of harmful products of combustion accumulate. Under no circumstances should the A.S.D be altered or bypassed in any way. Only a genuine Valor supplied replacement part should be fitted. The individual A.S.D components are not replaceable.
GENERAL INSTALLATION REQUIREMENTS This appliance is not suitable for installation in a room or internal space containing a bath or shower or where steam is regularly present or in a private garage. This appliance is suitable for the following: - A masonry chimney with a minimum diameter of 175mm (7”...
Fire Surround: This appliance may be installed with a surround with a minimum approved temperature rating of 150 degrees. The fire surround must be sealed to the wall. The appliance must be mounted on a Hearth Requirements: non-combustible hearth in accordance with Figure 4. The hearth material must have a minimum thickness of 12.5mm (1/2”...
CABLE RETENTION Cables and eyebolts are supplied for the retention of the appliance. Ensure that the internal fireplace components are sufficiently sound to take the eyebolts and wall plugs. These should be fitted in accordance with Figure 6, using the wall plugs and a No.10 drill.
that the pilot orifice is clear and that the thermocouple connections are sound. Replace the pilot unit if necessary (see servicing section of this manual). When the pilot is alight and stable, partially depress the knob and turn to “ LOW”. The pilot should then light the main burner at its low setting.
Page 10
Place the rear base coal in the burner compartment behind the front coal. It should rest on the ledge at the back of the burner compartment and its rear face should touch the rear ceramic wall (See Figure 12 & 13). Figure 12 Rear Base Coal Positioning Figure 13 Rear Base Coal in Position Install the 9 loose coals as...
This pilot unit incorporates a system that will automatically shut off the gas supply if the pilot flame goes out or if there is insufficient oxygen due to spillage or lack of ventilation. This monitoring system must not be adjusted, bypassed or put out of operation. This monitoring system, or any of its parts, must only be exchanged using Valor Authorised parts.
FINAL REVIEW Model 623 - Fit the top finials to the side pillars of the front casting. Place the front casting in position between the sides of the front surround. Place the bottom front cover casting below the front casting. Hand these instructions and the user’...
SERVICING & PARTS REPLACEMEMT Always turn off the gas supply before commencing any servicing. (The inlet elbow for this appliance incorporates an isolating valve). This product uses fuel effect pieces, burner compartment walls and gaskets containing Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres.
TO REMOVE THE GAS TAP/F.S.D • Remove the burner unit. • Disconnect the electrode lead from tab underneath the electrode. • Undo the thermocouple nut at the gas tap • Disconnect the inlet pipe at the tap end • Disconnect the pilot pipe at the tap end. •...
SHORT LIST OF SPARES DESCRIPTION NO. OFF PART NO. Injector Bray cat 18 size 360 For Natural Gas Appliances 541069 Injector Bray cat 18 size 170 For Propane Appliances 571709 Gas tap & spark generator 569429 Spark generator 521069 Control knob 545979 Pilot unit For Natural Gas Appliances 540979...
Type of fire. Model/Name. d) Serial Number. The fault, problem or request. General advice about gas and your gas fire: VALOR ADVICELINE 0345 626341. To report faults or arrange for your fire to be serviced: VALOR SERVICE 0121 386 6203.
Page 17
BS EN ISO 9001 quality system accepted by the British Standards Institute. The Highest Standards Valor is a member of the Society of British Gas Industries which works to ensure high standards of safety, quality and performance. Careful Installation Valor is a Corgi registered company.