3.5.9.2 I/O

The interface of I/O alarm configure is shown in Fig 3-18:
Fig 3-18
[I/O Type]: Select the I/O alarm type according to alarm trigger type: N.O. (normally open)
and N.C. (normally closed).
[Alarm Schedule]: Enable this function, user can set a daily schedule of I/O detection.
The start time should be earlier than the end time. You can copy and apply time settings to
the other date or every day. Click OK button to save your settings, click Refresh button to
update the schedule.
[Output]: Linkage alarm output with built-in relay when alarm is triggered.
[Delay]: The duration of linkage alarm output when alarm is triggered, range from 1 to
10s.
[Record]: Linkage recording and store in the SD card when alarm is triggered.
[Alarm Linkage]: The duration of linkage recording when alarm is triggered, time range:
5/10/30/60/120/300/600/900/1200/1800s.