Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
2.
Disconnect the AID cable from the connector on the SUB Board, and remove
the Card Slot Assy.
Connector on the SUB Board
Figure 4-239. Removing the Card Slot Assy (2)
Connect the AID cable properly to the connector on the SUB
Board. (See
Fig.
4-239.)
Align the grooves (x2) of the Card Slot Assy with the dowels (x2)
of the Base Frame. (See
When attaching the Grounding Plate, install it over the Card
Slot Assy, and tighten them together with the screw. (See
4-238.)
For routing the FFCs, see
After removing/replacing the Card Slot Assy, make the specified
A D J U S T M E N T
R E Q U I R E D
adjustments. (See
Chapter 5
DISASSEMBLY/ASSEMBLY
AID cable
Card Slot Assy
Fig.
4-238.)
Fig.
4.4 "Routing FFC/cables"
(p202).
"ADJUSTMENT".)
Disassembly/reassembly procedures specific to Artisan 700/PX700W/TX700W
4.3.3 Disassembling the Scanner Unit (Artisan 700/
PX700W/TX700W)
C H E C K
P O I N T
4.3.3.1 Document Cover
Parts/Components need to be removed in advance:
Scanner Unit/ADF Unit
Removal procedure
1.
Release the dowels (x2) and ribs (x2) of the Document Cover with the
Document Cover closed, and remove the Document Cover from the Scanner
Upper Housing in the direction of the arrow.
Scanner Upper Housing
Figure 4-240. Removing the Document Cover
Revision C
Document Cover
Dowel
Rib
Confidential
200