Transmission Holder Assy - Epson Artisan 700 Service Manual

Hide thumbs Also See for Epson Artisan 700:
Table of Contents

Advertisement

Epson Artisan 700/Epson Stylus Photo PX700W/TX700W

4.2.4.17 Transmission Holder Assy

The Main Frame becomes unstable once it is removed from the
C H E C K
Base Frame. Be careful not to deform the frame during
P O I N T
performing the following procedures.
Refer to
4.2.4.11 Main Frame (p144)
need to be removed before removing the Main Frame.
Parts/Components need to be removed in advance:
Main Frame/Printhead/CR Scale/Carriage Unit/Ink System
Removal procedure
1.
Push the Switch Lever in the direction of the arrow and disengage the
Transmission Arm from the Transmission Holder Assy. (See
4-140.)
2.
Remove the screw (x1) that secures the Transmission Holder Assy. (See
4-140.)
3.
Release the PE Sensor Cable from the Transmission Holder Assy, and remove
the Transmission Holder Assy.
PE Sensor Cable
Transmission Holder Assy
Figure 4-140. Removing the Transmission Holder Assy
DISASSEMBLY/ASSEMBLY
for the Parts/Components
Fig.
4-86,
Fig.
Fig.
Switch Lever
Transmission Arm
C.B.P. 3x8 (6±1Kgfcm)
Disassembly Procedures
Make sure that all gears on the Transmission Holder Assy are
properly installed to the hooks and move smoothly.
Figure 4-141. Installing the Transmission Holder Assy (1)
When assembling the Transmission Holder Assy, align the
hooks (x3) of the Transmission Holder Assy with the ribs (x3)
of the Main Frame.
Bottom side
Rib of the Main Frame
Figure 4-142. Installing the Transmission Holder Assy (2)
For routing the FFCs, see
4.4 "Routing FFC/cables"
Revision C
Hook
Transmission Holder Assy
Hook
(p202).
158
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Epson stylus photo px700fwEpson stylus photo tx700fw

Table of Contents