Cr Motor - Epson Artisan 700 Service Manual

Hide thumbs Also See for Epson Artisan 700:
Table of Contents

Advertisement

Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Align the positioning holes (x2) of the Holder with the dowels
(x2) of the Main Frame. (See
Insert the Compression Spring to the dowel of the Tensioner
and attach it to the protrusion of the Tension Holder
reinforcing plate. (See
After removing/replacing the PF Motor, make the specified
A D J U S T M E N T
R E Q U I R E D
adjustments. (See
After replacing the PF Motor, be sure to perform the required
lubrication. (See
Chapter 6
DISASSEMBLY/ASSEMBLY
Fig.
4-120.)
Fig.
4-119.)
Chapter 5
"ADJUSTMENT".)
"MAINTENANCE".)

4.2.4.15 CR Motor

The Main Frame becomes unstable once it is removed from the
C H E C K
Base Frame. Be careful not to deform the frame during
P O I N T
performing the following procedures.
Refer to
need to be removed before removing the Main Frame.
Parts/Components need to be removed in advance:
Main Frame
Removal procedure
1.
Loosen the CR Timing Belt, and detach the CR Timing Belt from the Pinion
Gear of the CR Motor. (See
2.
Remove the securing ring that secures the Spur Gear A, and remove the Spur
Gears (A, B) and Combination Gear (x1).
Combination Gear
Spur Gear A
Securing ring
Disassembly Procedures
4.2.4.11 Main Frame (p144)
for the Parts/Components
4.2.4.16 Carriage Unit Step2
Spur Gear B
Figure 4-124. Removing the CR Motor (1)
Revision C
-
Step4
(p155).)
152
Confidential

Hide quick links: