Scanner Carriage Unit - Epson Artisan 700 Service Manual

Hide thumbs Also See for Epson Artisan 700:
Table of Contents

Advertisement

Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
Artisan 700/
PX700W/TX700W
Figure 4-166. Routing the Grounding Wire
(Artisan 700/PX700W/TX700W)
DISASSEMBLY/ASSEMBLY
Grounding
Wire
Route the Grounding Wire between
the ribs
(x5) and frame.
Groove
Rib
Disassembly Procedures

4.2.5.3 Scanner Carriage Unit

Parts/Components need to be removed in advance:
Scanner Unit/ADF Unit/ Scanner Upper Housing/Scanner Motor Unit
Removal procedure
Some of the parts of Artisan 800/PX800FW/TX800FW differ from
C H E C K
those of Artisan 700/PX700W/TX700W.
P O I N T
Unless otherwise specified, this section describes the procedures for
Artisan 800/PX800FW/TX800FW. The differences that may affect
the disassembly/reassembly procedures of Artisan 700/PX700W/
TX700W will be provided in "Reassembly", etc.
Be careful no to damage the Rod Lens Array when removing
C A U T I O N
Scanner Carriage Unit.
Rod Lens Array
Figure 4-167. Handling the Scanner Carriage Unit
Revision C
169
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Epson stylus photo px700fwEpson stylus photo tx700fw

Table of Contents