Epson Artisan 700 Service Manual page 126

Hide thumbs Also See for Epson Artisan 700:
Table of Contents

Advertisement

Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
1.
Release the Plunger cable from the hooks (x10) of the Front Frame. (See
4-105.)
2.
Release the PE Sensor cable from the dowel of the Base Frame. (See
4-105.)
3.
Detach the relay connector of the PE Motor cable from the hole of the Base
Frame, and disconnect the connector. (See
Connector of the PF
Motor Cable
Hole of the Base Frame
Front Frame
Plunger Cable
Figure 4-105. Removing the Main Frame (1)
DISASSEMBLY/ASSEMBLY
Fig.
Fig.
Fig.
4-105.)
PE Sensor Cable
Dowel of the Base Frame
Hook
Disassembly Procedures
When removing the Main Frame, be careful not to damage the
C A U T I O N
cables and FFCs with the Main Frame.
4.
Remove the Grounding Plate B. (See
5.
Remove the screws (x7) that secure the Main Frame, and remove the Main
Frame from the Base Frame.
7
3
6
Positioning
4
hole & dowel
C.B.P. 3x8 (6±1Kgfcm)
Figure 4-106. Removing the Main Frame (2)
Revision C
Fig.
4-106.)
Grounding
Plate A
(Under the
Frame)
5
1
2
Grounding
Plate B
145