WatchNet ENX Series Manual page 96

Table of Contents

Advertisement

Please refer to the following sheet for detailed information.
Parameter Function
Event
The abnormal events include: no disk, no space, disk error, offline, IP
Type
conflict.
You need to check the box here to enable this function.
Threshold: It refers to the HDD free space.
Normal
The corresponding alarm output channel when alarm occurs.
Out
The alarm output channel may vary. The interface here is for reference
only.
Latch
The alarm output can delay for the specified time after alarm stops. The
value ranges from 10s to 300s.
Record
After you selected the disk connection option, once the device is offline,
channel
the activated channel can begin alarm record.
Record
System can delay the record for specified time after alarm ended. The
latch
value ranges from 10s to 300s.
Send
If you enable this function, system can send out email to alarm the
email
specified user.
Show
Once you check the box to enable this function, system can display the
message
alarm icon on the right of the channel name at the local end.
5.3.3.4 Alarm I/O
Here you can search alarm output status. See Figure 5-42.
Figure 5-41 Abnormality -2
90

Advertisement

Table of Contents
loading

Related Products for WatchNet ENX Series

Table of Contents