Once you change the HDD Group settings, system will pack the records and then begin
record again!
After you removed one HDD channel group, corresponding channel record will be saved on
the HDD of the same group.

3.7.2 Abnormality

Abnormality interface is shown as in Figure 3-74.
Event type: There are several options for you such as disk error, no disk, disconnection,
IP conflict, MAC conflict, redundant power and etc.
Alarm output: Please select alarm activation output port (multiple choices).
Latch: Here you can set corresponding delaying time. The value ranges from 1s-300s.
System automatically delays specified seconds in turning off alarm and activated output after
external alarm cancelled.
Show message: system can pop up the message in the local screen to alert you when
alarm occurs.
Alarm upload: System can upload the alarm signal to the network (including alarm centre)
if you enabled current function.
Send email: System can send out email to alert you when alarm occurs.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when alarm occurs.
Figure 3-73
Figure 3-74