and etc will not be activated. For example, if you set the anti-dither time as 10 second, you
can see the each activation may last 10s if the local alarm is activated. During the process, if
system detects another local alarm signal at the fifth second, the buzzer, tour, PTZ
activation, snapshot, record channel will begin another 10s while the screen prompt, alarm
upload, email will not be activated again. After 10s, if system detects another alarm signal, it
can generate an alarm since the anti-dither time is out.
Alarm output: The number here is the device alarm output port. You can select the
corresponding ports(s) so that system can activate the corresponding alarm device(s) when
an alarm occurred.
Latch: When the anti-dither time ended, the channel alarm you select in the alarm output
may last the specified period. The value ranges from 1 to 300 seconds. This function is not
for other alarm activation operations. The latch is still valid even you disable the alarm event
function directly.
Show message: System can pop up a message to alarm you in the local host screen if you
enabled this function.
Alarm upload: System can upload the alarm signal to the network (including alarm centre
and the WEB) if you enabled current function. System only uploads the alarm channel status.
You can go to the WEB and then go to the Alarm interface to set alarm event and alarm
operation. Please go to the Network interface to set alarm centre information.
Send email: System can send out the alarm signal via the email to alert you when alarm
occurs.
Record channel: you can select proper channel to record alarm video (Multiple choices).
You need to set alarm record mode as Schedule in Record interface (Main Menu-
>Advanced->Record). Please note the manual record has the highest priority. System
record all the time no matter there is an alarm or not if you select Manual mode.
Now you can go to the Schedule interface (Main Menu->Setting->Schedule) to set the
record type, corresponding channel number, week and date. You can select the record
type:Regular/MD/Alarm/MD&Alarm. Please note, you can not select the MD&Alarm and
MD(or Alarm) at the same time.
Now you can go to the Encode interface to select the alarm record and set the encode
parameter (Main Menu->Setting->Encode).
Finally, you can set the alarm input as the local alarm and then select the record
channel. The select channel begins alarm record when an alarm occurred. Please note
system begins the alarm record instead of the MD record if the local alarm and MD
event occurred at the same time.
Tour: Here you can enable tour function when alarm occurs. System supports 1/8-window
tour. Please go to chapter 3.5.7 Display for tour interval setup. Please note the tour setup
here has higher priority than the tour setup you set in the Display interface. Once there two
tours are both enabled, system can enable the alarm tour as you set here when an alarm
occurred. If there is no alarm, system implements the tour setup in the Display interface.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when alarm occurs.
Please highlight icon
please click save button, system goes back to the previous menu.
to select the corresponding function. After setting all the setups