2JB/2JC

(18) Image center does not align with the original center.

Copy example
Misadjusted image center line.
Misadjusted scanner center line.
Original is not placed correctly.
1-4-40
Causes
Check procedures/corrective measures
Run maintenance item U034 to readjust the center line of
image printing (see page 1-3-13).
Run maintenance item U067 to readjust the scanner leading
edge registration (see page 1-3-20).