830
Users Manual
Remember not to touch mounted components! This includes the brackets and
the support posts, which are NOT to be used to rotate the shafts .
It is advisable to turn shafts in the same direction as the machine normally
rotates, in case the shafts shift from their normal seating in the bearings.
You may begin measurement by turning the shafts even if the beam is not
centered exactly at the center of the crosshair.
END or OFF? Extend
If 'Laser END' or 'Laser OFF' appears on the screen during the turning of the
shafts, the laser has shifted away from the detector due to gross or large mis-
alignment or long beam travel. If this happens, then use the 'Extend' function to
expand the measurement range. This function is described on page 102.
Diagnose
The diagnosis is prompted automatically after the set number of measurements
points have been taken.
70
Note