Sensor to coupling center
This is the distance between the marking on top of the sensor and the coupling
center.
This dimension is calculated automatically as half the entered sensor to prism
distance. The value may be edited directly in the editing box that appears and
value confirmed by pressing
Coupling diameter
The coupling diameter can be obtained by measuring the circumference of the
coupling and dividing the value by 3.142 (p).
The default value is 100 mm (10" if set to US imperial customary units). Should
there be need to edit the value, use the data entry keys to enter value in the
editing box that appears, then confirm entry by pressing
arrows advance to the next required distance automatically.
RPM (revolutions per minute)
The default value is 1500 (1800 if set to US imperial customary units). Should
there be need to edit the value, use the data entry keys to enter value in the
editing box that appears, then confirm entry by pressing
arrows advance to the next required distance automatically.
Coupling center to front foot, right machine
This is the distance from the center of the coupling to the pair of feet on the right
machine nearest to the coupling.
Front foot to back foot, right machine
This is the distance between the front and back feet of the right machine.