Connect The Y-Axis Table Wires To The Board - FELIXrobotics Felix 1.0 Instruction Manual

Revision e
Table of Contents

Advertisement

To prevent the power supply from being damaged, place some tape on
the grill. Solder residu particles can easily fall in and cause a short.
From the big ATX connector, cut 2 yellow and 2 black wires near the
connector. (It does not matter which of the black or yellow wire you take.)
You need this length to be able to reach the ramps case. Strip the ends
and put some solder on it. Then connect them according to the
schematics of the ramps electronics.
The order of the cables for the screw terminal in more detail.
From left to right.
2x Hot-end powerresistor cables, airduct fan black, airduct fan red, 2x
heated bed powerresistor cables, 12V yellow, COM black, 12V yellow,
COM black.
The wire colors of the hot-end and heated bed can be different from the
wires in the picture.
Make sure the polarity of the fan cables are according to the schematics!!!
Otherwise the fan will be damaged.
info@felixprinters.com
www.felixprinters.com
When finished with connecting as much as possible, guide the RAMPS
electronics into the casing. Make sure the edges of the RAMPS case slide
in the designed slots shown in green.
Finally push it down untill the edge to secure it.

Connect the y-axis table wires to the board.

10.3
We first connect the cables of the y-axis table to the ramps board. This is
because the pre-crimped wire to the thermistor has a leading length for
the cable loop.