Monitoring and Analyzing Switch Operation
Port and Static Trunk Monitoring Features
B-26

CLI: Configuring Port and Static Trunk Monitoring

Port and Static Trunk Monitoring Commands Used in This Section
show monitor
below
mirror-port
page B-26
monitor
page B-27
You must use the following configuration sequence to configure port and static
trunk monitoring in the CLI:
1.
Assign a monitoring (mirror) port.
2.
Designate the port(s) and static trunk(s) to monitor.
Displaying the Monitoring Configuration. This command lists the port
assigned to receive monitored traffic and the ports and/or trunks being
monitored.
Syntax:
show monitor
For example, if you assign port A6 as the monitoring port and configure the
switch to monitor ports A1 - A3, show monitor displays the following:
Figure B-21. Example of Monitored Port Listing
Configuring the Monitor Port. This command assigns or removes a mon­
itoring port, and must be executed from the global configuration level. Remov­
ing the monitor port disables port monitoring and resets the monitoring
parameters to their factory-default settings.
[no] mirror-port [< port-num >]
Syntax:
For example, to assign port A6 as the monitoring port:
HPswitch(config)# mirror-port a6
Port receiving monitored traffic.
Monitored Ports