HP ProCurve Series 4100GL Management And Configuration Manual page 317

Hide thumbs Also See for ProCurve Series 4100GL:
Table of Contents

Advertisement

Internal VLAN Number for the Default VLAN
Note: Internal VLAN numbers reflect the sequence
in which VLANs are created, and are not related to
the unique VID assigned to each VLAN. (See the
"Note on VLAN Numbers on page 13-16.)
Figure 13-4. Example of a Forced Fast-Leave Listing where all Ports are Members of the Default VLAN
3. Enter either of the following walkmib command options:
walkmib hpSwitchIgmpPortForcedLeaveState
- OR ­
walkmib 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.3.1.5
The resulting display lists the Forced Fast-Leave state for all ports in the
switch, by VLAN. (A port belonging to more than one VLAN will be listed
once for each VLAN, and if multiple VLANs are not configured, all ports
will be listed as members of the default VLAN.) The following command
produces a listing such as that shown in figure 13-4:
Ports 1-6: 6- Port 109/1000T Module in Slot A
To List the Forced Fast-Leave State for a Single Port. (See the "Note
on VLAN Numbers" on page 13-16.)
Go to the switch's command prompt and use the
below.
Syntax:
getmib hpSwitchIgmpPortForcedLeaveState.<vlan number>
- OR ­
getmib 1.3.6.1.4.1.11.2.14.11.5.1.7.1.15.3.1.5.<vlan number>
For example, the following command to list the state for port A6 (which,
in this case, belongs to the default VLAN) produces the indicated listing:
Multimedia Traffic Control with IP Multicast (IGMP)
Sequential Port
Numbers
How IGMP Operates
2
The
at the end of a port
listing shows that Forced
Fast-Leave is disabled on
the corresponding port.
1
The
at the end of a port
listing shows that Forced
Fast-Leave is enabled on
the corresponding port.
command, as shown
getmib
<.port number>
<.port number>
13-17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents