N o t e
General Switch Software Download Rules
A switch software image downloaded through the menu interface always
■
goes to primary flash.
■
After a switch software download, you must reboot the switch to imple
ment the newly downloaded code. Until a reboot occurs, the switch
continues to run on the software it was using before the download started.
Downloading new switch software does not change the current switch con-
figuration. The switch configuration is contained in separate files that can also
be transferred. Refer to "Transferring Switch Configurations" on page A-13.
In most cases, if a power failure or other cause interrupts a flash image
download, the switch reboots with the image previously stored in primary
flash. In the unlikely event that the primary image is corrupted (which may
occur if a download is interrupted by a power failure), the switch goes into
boot ROM mode. In this case, use the boot ROM console to download a new
switch software image to primary flash. Refer to "Restoring a Flash Image" on
page C-41.
Using TFTP To Download Switch Software from a
Server
This procedure assumes that:
An switch software file for the switch has been stored on a TFTP server
■
accessible to the switch. (The switch software file is typically available
from the HP ProCurve website at http://www.hp.com/go/hpprocurve.)
The switch is properly connected to your network and has already been
■
configured with a compatible IP address and subnet mask.
■
The TFTP server is accessible to the switch through IP.
Before you use the procedure, do the following:
■
Obtain the IP address of the TFTP server in which the switch software file
has been stored.
If VLANs are configured on the switch, determine the name of the VLAN
■
in which the TFTP server is operating.
■
Determine the name of the switch software file stored in the TFTP server
for the switch (for example, G0721.swi).
File Transfers
Downloading Switch Software
A-3