Printer Specifications - Oce Arizona 6160 XTS User Manual

Table of Contents

Advertisement

Printer Specifications

Printer Specifications
Introduction
The Océ Arizona 6160/6170 XTS printers are capable of producing large format images on various
rigid and flexible media. The printers consist of a flatbed vacuum table and a moving gantry with
a printhead carriage. Media is held flat and stationary on the vacuum table during printing. The
gantry contains a carriage that sweeps across the table as the gantry moves in steps along the
length of the table to print an image on the media.
Printer Specifications
The printer must be operated in accordance with the environmental conditions specified in the
Océ Arizona Site Preparation Guide. Note that there are safety requirements and precautions
indicated in this document. Be sure to read all of the safety sections before using the printer.
NOTE
All specifications in this document are subject to change without notice. While due caution has
been exercised in the production of this document, possible errors and omissions are
unintentional.
Specifications
Feature
Printing Technology
Maximum Media Size
Media Thickness
Maximum Print Size
Media Weight
Nozzle Drop Volume:
User Interface
Curing System
Power Requirements
Voltage:
(Rated Current: 16A)
Compressed air is required
See the Site Preparation
Guide for details
Environmental Conditions
BTU Output
Hardware Interface
Image Processing Software THRIVE® (preferred) or ONYX® ProductionHouse Océ Edition ver-
14
Chapter 1 ‐ Introduction
Specification
Piezoelectric inkjet with Océ VariaDot™ technology
2.5m (98.4") x 3.05m (120.1")
Maximum: 50.8 mm (2.0")
2.51m (98.8") x 3.06m (120.5")
Maximum: 34 kg/m² (7 lbs/ft²)
Variable droplet sizes: 6 to 42 picolitres
LCD flat-panel monitor and mouse on a user positioned podium.
UV curing lamps with variable power settings.
200-240VAC 50/60Hz 30A (Delta)
347-415VAC 50/60Hz 20A (Wye)
Continuous power consumption: 9.6kW (max)
Recommended Circuit Breaker:
North America 20A, European Union 16A.
Pressure (max): 120 psi Peak
flow: 12 cfm at 100psi
Continuous flow: 2cfm at 100psi
For temperature, humidity, and other operational requirements,
refer to the Océ Arizona 600 Site Preparation Guide available from
http://dgs.oce.com/.
10,000 BTU (2950 watts) under continuous operation.
USB, Ethernet TCP/IP, 100 base-T (or Gigabyte, if supported by the
local network).
sion X11.
Océ Arizona 6100 Series

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Arizona 6170 xts

Table of Contents