Symbol Definitions

]
= CR/LF (carriage return + line feed) (hex 0D 0A)
}
= Soft carriage return (no line feed, hex 0D)
(For web browser commands, use the
|
= Pipe (vertical bar) character
= Space
24
= The
24
superscript indicates commands that give an E24 (privilege violation) message if you are not logged in at the
administrator level.
E
= Escape key (hex 1B) (For web browsers, use W instead of E.)
X!
= Power receptacle (1-4)
X#
= Greenwich Mean Time (GMT) offset value
(-12.00 to +14.00) represents the time difference in hours and minutes (±hh:mm) relative to Greenwich, England. The
plus sign and leading zero are optional. For example, 5:30 = +05:30.)
X%
= On or Off status
0 = off or disabled
1 = on or enabled
X^
= Dirty memory status
1 = RAM needs to be saved to flash memory.
0 = RAM has been saved to flash (OK to power off or reset).
X1!
= Version (typically listed to two decimal places, that is, n.nn)
X1@
= Unit name. The name of the PC1 is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9),
and minus sign or hyphen (
between upper and lower case.
NOTE:
The first character must be a letter. The last character must not be a minus sign or hyphen (
X1#
= Local date and time format
Set format (MM/DD/YY-HH:MM:SS).
Example: 11/18/03-10:54:00.
Read format (day of week, day month year HH:MM:SS).
Example: Tue, 18 Nov 2011 18:19:33.
X1$
= IP address (nnn.nnn.nnn.nnn
suppressed in returned values.
X1%
= E-mail domain name (for example: extron.com)
X1*
=
Hardware (MAC) address (xx-xx-xx-xx-xx-xx).
X1(
=
Subnet mask (nnn.nnn.nnn.nnn). Leading zeros are optional in setting values in each of four fields, and they are
suppressed in returned values.
X2@
For verbose response mode:
0 = clear or none
1 = verbose mode
2 = tagged responses for queries
3 = verbose mode and tagged responses for queries
Default = 0
NOTE:
If tagged responses are enabled, all read commands return the constant string plus the data, like
setting the value does.
Example:
Command:
Response:
X3#
Password (minimum length = 4 characters; maximum length = 12 characters.
=
No special characters are allowed.
|
[pipe] character instead of the soft return.)
-
). No blank or space characters are permitted as part of a name. No distinction is made
)
. Leading zeros in each of four fields are optional in setting values, and they are
}
E CN
Ipn • X1@
IPL T PCS4 • SIS Programming and Control
-
).