Extron electronics IP LINK IPL T PCS4 User Manual page 56

Ip link power control interfaces
Table of Contents

Advertisement

Command
Firmware Version, Part Number, and Information Requests
Query firmware version
Query firmware information
Query bootstrap version
Query factory firmware version
Query updated firmware version
Query verbose version information
NOTE:
An asterisk (*) after a version number indicates the version that is currently running. Question marks (?.??)
indicate that only the factory firmware version is loaded. A caret (^) indicates the firmware version that should be
running; however, a mode 1 reset was executed and the factory default firmware version is currently loaded. An
exclamation point (!) indicates corrupted firmware.
Request interface part number
Request model name
Request model description
Request system memory usage
Request user memory usage
E-mail Commands
Configure e-mail events
(mailbox)
24
Example:
View e-mail events (mailbox)
Send e-mail events (file named in
mailbox)
24
Send e-mail (using different file)
Web Browser-specific Commands
Read response from last URL cmd
Mail Server Setup Commands
Set mail server IP, unit domain
name
24
View mail server IP, unit domain
name
ASCII (Telnet)
(Host to Switcher)
Q
1Q
2Q
3Q
4Q
0Q
N
1I
2I
3I
4I
E X4%
,
X4^
,
X4&
CR
}
E
5,jdoe@extron.com,7.emlCR
E X4%
CR
}
E X4%
SM
}
E X4%
,
X7)
,
X4&
SM
}
24
E
UB
}
E X1$
,
X1%
CM
}
E
CM
}
URL Encoded (Web)
(Host to Switcher)
Q
1Q
2Q
3Q
4Q
0Q
N
1I
2I
3I
4I
W
X4%
%2C
X4^
%2C
X4&
CR
|
}
W5%2Cjdoe%40extron%2Ecom%2C7%2EemlCR|
Ipr5,jdoe@extron.com,7.eml
W
X4%
CR
|
W
X4%
SM
|
W
X4%
%2C
X7)
%2C
X4&
SM
|
W UB
|
W
X1$
%2C
X1%
CM
|
W CM
|
IPL T PCS4 • SIS Programming and Control
Response
(Switcher to Host)
X1! ]
X1! ]
X1! ]
X1!
plus (web version –
model – UL – date and
time)
]
X1!
plus (web version –
model – UL – date and
time)
]
Sum of responses from
2Q, 3Q, and 4Q
]
60-544-07 or
60-544-09
]
IPL T PCS4 or
]
IPL T PCS4i
Lists four switched
110 VAC or 220 VAC
receptacles with current
]
threshold sensing.
Number of bytes and
Kbytes used out of
the number of total
Kbytes
]
Number of bytes and
Kbytes used out of
the number of total
Kbytes
]
,
,
Ipr
X4%
X4^
X4& ]
]
,
X4^
X4& ]
Eml
X4^ ]
Eml
X4^ ]
Response from
command
]
,
Ipm
X1$
X1% ]
,
X1$
X1% ]
50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip link ipl t pcs4i

Table of Contents