Network Connections

1.
Check the network connections and make adjustments as needed. The Link LED is
solid green if a network connection is detected. The yellow ACT LED blinks if there is
activity on the network. If these LEDs are not lit, either the cable is faulty or not plugged
in, or the wrong type of cable is being used (see
"Installation and Rear Panel" section).
2.
At the DOS command prompt, try to ping the unit by entering ping and the IP address
assigned to your PCS4 (see
connected, you receive the following response to your
Figure 34.
If the connection was not made, the following response appears:
Figure 35.
If you get a response indicating that the ping was unsuccessful, do the following:
Make sure your unit is using the appropriate subnet mask (check with your system
administrator).
Make sure your computer does not have a software firewall program which might
block the IP address of the unit.
3.
If contact is established with the unit, but the unit web pages cannot be accessed by
your web browser, verify (in the Options or Preferences menu) that your web browser is
configured for direct network connection and not set up to use a proxy server.
If you are still experiencing problems, contact the Extron S3 Sales & Technical Support
Hotline (see the last page of this guide for
"Setting Up the Computer Using
Successful Ping Command Response
Response to an Unsuccessful Ping Command
contact
IPL T PCS4 • HTML Configuration and Control
"Connecting the
Devices" in the
ARP"). If the PCS4 is
command:
Ping
information).
41