Extron electronics IP LINK IPL T PCS4 User Manual page 22

Ip link power control interfaces
Table of Contents

Advertisement

3.
If the PCS4 has never been configured and is still set for factory defaults, skip to step 4.
If not, perform a mode 4 system reset to restore the factory-set values (see
the
Unit" in the "Front Panel Features and Operations" section for the resetting
procedure).
NOTE:
The PCS4 must be configured with the factory default IP address
(192.168.254.254) before you execute the ARP command, as described
below.
4.
On the computer, access the command prompt, then enter
address for the PCS4, a space, and finally the PCS4 MAC address (taken from the label
on the rear panel). For example:
arp -s 10.13.170.15 00-05-A6-00-0A-90
A space must separate
Figure 9.
ARP-S Command Screen
NOTE:
After the
arp -s
and starts responding to ping requests, as described in the next step.
5.
To verify that the new address has been set, execute a ping command by entering
followed by the new IP address, at the command prompt.
NOTE:
Ping is a utility or diagnostic tool that tests network connections. It is used to
determine if the host has an operating connection and is able to exchange
information with another host.
Example:
ping 10.13.170.15
Ping is a utility or diagnostic tool that tests network connections. It is used to determine
if the host has an operating connection and is able to exchange information with
another host.
arp
from the hyphen (
-
).
command is issued, the PCS4 changes to the new address
IPL T PCS4 • HTML Configuration and Control
"Resetting
, the desired new IP
arp -s
ping
16
,

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip link ipl t pcs4i

Table of Contents