Setting the Standby power threshold
1.
Power off the attached device.
2.
Press and hold the Standby button (shown at right).
3.
While holding down the Standby button, press and release the
receptacle button for the same device for which you set the Full
threshold. The Standby LED for the selected receptacle blinks twice and remains lit.
1
F
Standby
LED
S
Receptacle Button
4.
Release the Standby button.
5.
Repeat steps 1 through 9 for any other receptacles to which you have connected devices
to be controlled through the PCS4.
NOTE:
Settings that are made via the front panel for power output receptacles
and reference thresholds take approximately two minutes to be stored in
memory. If you recycle power too soon after settings have been made, the
settings are lost.
These threshold settings are preserved if the PCS4 AC power is recycled or if power is
removed from an attached device. For example:
If the receptacle
And the power level...
is set to...
Full
drops below the stored threshold
drops below the stored Standby
threshold
Standby
exceeds the stored Standby threshold F LED lights.
To indicate that the configuration has been saved, both the Standby LED and the Full LED
light and remain lit when those thresholds are selected.
None and Not Set thresholds
When a Full or Standby reference threshold has been set for a receptacle at some time, and
neither threshold is detected, a threshold status of
be the response to SIS queries.
threshold is a state that is detected; it cannot be set manually.
If a receptacle has never been set to a Full or Standby reference threshold, its threshold
status is shown as
Not Set
default setting for reference thresholds.
None
also appears if the receptacle is powered off. The None
None
on the web page and in response to SIS queries. Not Set is the
IPL T PCS4 • Front Panel Features and Operation
SET REFERENCE
STANDBY
The receptacle...
F (Full) led shuts off, and the
S (Standby) LED lights.
S LED shuts off.
appears on the web page or can
FULL
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip link ipl t pcs4i

Table of Contents