Extron electronics IP LINK IPL T PCS4 User Manual page 16

Ip link power control interfaces
Table of Contents

Advertisement

There are two common types of power for electronic devices: soft and hard.
Soft power devices normally have three power states: On, Standby, and Off. Such
devices include projectors, DVD players, and VCRs.
Example: On soft power devices, the Standby mode allows the unit to be powered
to its Full power mode via RS-232 commands or a remote. Pressing a PCS4 receptacle
button to Off when the receptacle is connected to a device that supports Standby power
causes the device to power off.
Hard power devices normally have two power states: On and Off. These devices
include Extron switchers and interfaces.
Example: On Extron switchers, there is no power button or Standby condition, and the
unit power can be set only to On and Off from the PCS4 front panel. Therefore, when
the power is on, it is at Full power, and can be set for Full reference threshold.
The Full and Standby reference thresholds must be configured with the device attached to
the PCS4 receptacle. The thresholds must be set in the correct order, with Full being set
first. Follow these steps to set the threshold for each device, using the front panel. (These
thresholds also can be configured using the web pages or SIS commands.)
NOTE:
The Full threshold must be set first. If Standby is set first, the Standby reference
setting is removed by the setting of the Full reference threshold.
1.
Connect a device to a power output receptacle on the IPL T PCS4. Make a note of the
receptacle number to which you connected it (1 through 4).
2.
Press the corresponding front panel button to activate the receptacle. Check to ensure
that the Power LED for the receptacle is lit.
Setting the Full power threshold
1.
Power on the attached device.
2.
Press and hold the Full button on the PCS4 front panel (shown at right).
3.
While holding the Full button, press and release the button for the
receptacle into which the device is plugged. Both the F (Full) LED and the
S (Standby) LED for the selected receptacle blink twice. Only the Full LED remains lit.
1
F
Full
LED
S
Receptacle Button
4.
Release the Full button. The Full threshold for the receptacle is now set.
IPL T PCS4 • Front Panel Features and Operation
SET REFERENCE
FULL
STANDBY
10

Advertisement