RS-232/USB-Com Interfaces

Disable Character

Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with
normal operation of these characters. 8-bit data is not recognized when the option
has been set as 7 Data Bits.
See
page 260
for more information on setting this feature.
$CR2DC
Select Disable Character Setting

Enable Character

Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with
normal operation of these characters. 8-bit data is not recognized when the option
has been set as 7 Data Bits.
See
page 261
in "References" for more information on setting this feature.
$CR2EC
Select Enable Character Setting
Product Reference Guide
0x44 = Disable Character is 'D'
DEFAULT
DEFAULT
0x45 = Enable Character is 'E'
Enter/Exit Programming Mode