Enter/Exit Programming Mode

UPC-A

The following options apply to the UPC-A symbology.

UPC-A Enable/Disable

When disabled, the reader will not read UPC-A bar codes.
$CABEN01(CR)
UPC-A = Enable

UPC-A Check Character Transmission

Enable this option to transmit the check character along with UPC-A bar code data.
$CABCT01(CR)
UPC-A Check Character Transmission = Send
112
$CABEN00(CR)
UPC-A = Disable
DEFAULT
$CABCT00(CR)
UPC-A Check Character Transmission = Don't Send