STAR Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the handheld reader and
Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (number of readers in the
same area). The selectable range for this feature is from 02 to 25 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 25 =
3. Go to
4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See
Table 47. STAR Radio Protocol Timeout Examples
STEP
ACTION
1
Desired Setting
2
Pad with leading zero(es)
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
286
25, etc
page 249
and scanScan the ENTER/EXIT PROGRAMMING MODE barcode to
enter Programming Mode.
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
Mode.
2 Seconds
02
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECTSTAR RADIO PROTOCOL TIMEOUT SETTING
'0' and '2'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix D,
Table 47
for some examples of how to set this feature.
EXAMPLES
5 Seconds
10 Seconds
05
'0' and '5'
Gryphon™ I GD44XX/GBT4400/GM440X
Keypad, that represent
25 Seconds
10
25
'1' and '0'
'2' AND '5'