Stand Mode Off Time

This feature specifies the amount of time reader illumination stays off after pulling the trigger
when in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms
to 16 seconds).
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 20 = 20,
3. Go to
4. Scan the bar code: Set Stand Mode Illuminator Off Time.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
This completes the procedure. See
Table 39. Stand Mode Off Time
STEP
ACTION
1
Desired Setting
2
Pad leading zero
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
278
etc.
page 101
and scan the ENTER/EXIT PROGRAMMING MODE bar code to
enter Programming Mode.
the setting which was determined in the steps above. You will hear a two-beep indication
after the last character.
Mode.
500 ms
01
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT STAND MODE OFF TIME
'0' and '1'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix D,
Table 39
for some examples of how to set this feature.
EXAMPLES
1 Second
5.5 Seconds
02
'0' and '2'
Gryphon™ I GD44XX/GBT4400/GM440X
Keypad, that represent
16 Seconds
11
32
'1' and '1'
'3' and '2'