Datalogic Gryphon I GBT4400 Quick Reference Manual

Datalogic Gryphon I GBT4400 Quick Reference Manual

General purpose handheld area imager bar code reader with bluetooth wireless technology
Hide thumbs Also See for Gryphon I GBT4400:

Advertisement

Gryphon™ I GBT4400
General Purpose Handheld
Area Imager Bar Code Reader
with Bluetooth® Wireless Technology
Quick Reference Guide

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic Gryphon I GBT4400

  • Page 1 Gryphon™ I GBT4400 General Purpose Handheld Area Imager Bar Code Reader with Bluetooth® Wireless Technology Quick Reference Guide...
  • Page 2 Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or "Datalogic ADC"). Owners of Datalogic...
  • Page 3: Table Of Contents

    Replacing the Batteries ..............12 Using the Gryphon™ I GBT4400 ............14 Linking the Reader ..................15 Link Datalogic RF Devices to Base ......... 15 Link Scanner to Bluetooth Adapter....... 15 Power Off ...................... 16 Selecting the Interface Type ..............16 Interface Selection .................
  • Page 4 FCC RF Radiation Exposure Statement ......44 Canadian Notice ................44 Power Supply ................... 44 Imager Labeling ................47 Aiming System..............47 WEEE Statement ................52 Datalogic ADC Limited Factory Warranty ......53 Ergonomic Recommendations ............. 55 Services and Support ................56...
  • Page 5: End User License Agreement

    Agreement. If you do not intend to be bound to the terms of this Agreement, Datalogic is not willing to license the Software to you, you may not use the Datalogic Product or the Software, and you must contact the party from whom you acquired the Datalogic Product for instructions.
  • Page 6: Limited Warranty

    End User shall not sell, assign, sublicense, distribute, lend, rent, give, or other- wise transfer the Datalogic Product to any third party unless such third party agrees with Datalogic in writing to be bound by the terms and conditions of this Agreement. Any such transfer of the Datalogic Product absent such agree- ment shall be null and void.
  • Page 7: Limitation Of Liability

    Datalogic ADC, Inc., Legal Department, 959 Terry Street, Eugene, OR 97402. In the defense or settlement of any such claim, Datalogic may, at its option, 1) procure for End User the right to continue using the Datalogic Product, 2)
  • Page 8: Software Product Policy

    - END - Software Product Policy Datalogic reserves the right to ship its products with the latest version of software/ firmware available. This provides our customers with the very latest in Datalogic soft- ware technology.
  • Page 9: Description

    Gryphon™ I GBT4400 Description With rich feature sets and extensive options, the Gryphon™ product series from Datalogic represents the premium level of data collection equipment for general purpose applications. The Gryphon GBT4400 readers have enhanced optics with improved motion tolerance allowing codes placed on fast...
  • Page 10: Setting Up The Reader

    Setting Up the Reader Setting Up the Reader Follow the steps below to connect and get your reader up and communicating with its host. Configure the Base Station starting on this page. Charge the Batteries (see page 10). Link to the Base Station (see page 15). Select the Interface Type (see page 16).
  • Page 11 Setting Up the Reader Insert the appropriate parts for the desired base station position, as shown below. Standing, Horizontal Horizontal Only or Vertical Using your thumbs, push open the plastic tabs on the bottom of the base to free the wing holders. To ensure best contact and performance, do not intermix the parts of the two different mount sets.
  • Page 12: Connecting The Base Station

    Connecting the Base Station The stand can now be repositioned in either horizon- tal or standing position. Horizontal Standing Connecting the Base Station shows how to connect the Base Station to a Figure 1 on page 5 terminal, PC or other host device. Turn off the host before connection and consult the manual for that equipment (if necessary) before proceeding.
  • Page 13: Securing The Dc Power Cord (Optional)

    Connecting the Base Station Figure 1. Connecting the Base Station Wall plug Connector I/F Cable AC/DC Adapter DC Power Cord Base Station Securing the DC Power Cord (Optional) The DC power cord for the adapter can be secured to the bot- tom of the base in order to maximize the mechanical retention of the cable itself.
  • Page 14 Host Connection: ble type is compatible with your host equipment. The Gryphon I GBT4400 can be set up to require a PIN code when connecting to the host. If you are adding new equip- ment to a system that uses a custom security PIN, please see the PRG for information before proceeding.
  • Page 15: System And Network Layout

    Connecting the Base Station Plug the AC Adapter into an approved AC Power Connection: wall socket with the cable facing downwards (as shown in Fig- ) to prevent undue strain on the socket. ure 1 To detach the cable, insert a paper clip Disconnecting the Cable: or similar object into the hole on the base, as shown.
  • Page 16: Using The Bc40Xx™ Radio Base

    Connecting the Base Station Using the BC40xx™ Radio Base Radio Base LEDs LEDs on the Gryphon Base provide information about the Base as well as battery charging status, as shown in Figure 7 Figure 7. Gryphon Base LEDs YELLOW LED BUTTON RED LED —...
  • Page 17: Cleaning

    Cleaning Cleaning Exterior surfaces and scan windows exposed to spills, smudges or debris require periodic cleaning to ensure best performance during scanning operations. Contacts on the scanner and the base should also be cleaned as needed to ensure a good connec- tion.
  • Page 18: Charging The Batteries

    ) will indicate the sta- Table 1 tus of the battery. Before using the Battery, read “Battery Safety” in the follow- ing section. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum perfor- mance. Battery Safety To install, charge and/or perform any other action on the bat- tery, follow the instructions in this manual.
  • Page 19 Always charge the battery at 32° – 104°F (0° - 40°C) tem- perature range. Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. CAUTION The use of any other power supplies can damage the device and void your warranty.
  • Page 20: Replacing The Batteries

    US and China regulatory and other laws and regulations about the environment. Replacing the Batteries Before proceeding, read “Battery Safety” on the preced- ing pages. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum perfor- mance. Use the following procedure to change the reader’s battery: With a screwdriver, unscrew the battery cover screw.
  • Page 21 Charging the Batteries Unplug the white connector, and remove the two screws securing the battery holder. Connector Screw Screw Carefully lift out the gold contacts circuit, and remove the battery holder cap while letting the white connec- tor pass through the hole in the battery holder (as shown below).
  • Page 22: Using The Gryphon™ I Gbt4400

    Successful reading is signaled by an audible tone plus a good-read green spot LED indicator. Reference the Gryphon I GBT4400 Product Reference Guide (PRG) or Datalogic Aladdin configuration software (both available on the Datalogic website) for more information about this feature and other programmable settings.
  • Page 23: Linking The Reader

    Enable RF Link to Server The Gryphon I GBT4400 can be set up to require a PIN code when connecting. If you want to set up a PIN, or when add- ing new equipment to a system that uses a custom security PIN, please see the PRG for information.
  • Page 24: Power Off

    Power Off Power Off Scan the bar code below to shut off power to the BT handheld until the next trigger pull. PowerOff Selecting the Interface Type Upon completing the physical connection between the reader and its host, proceed directly to Interface Selection below for information and programming for the interface type the read- er is connected to (for example: RS-232, Keyboard Wedge, USB, etc.) and scan the appropriate bar code to select your sys-...
  • Page 25 Selecting the Interface Type RS-232 RS-232 standard interface Select RS232-STD RS-232 Wincor-Nixdorf Select RS232-WN RS-232 for use with OPOS/UPOS/JavaPOS Select RS-232 OPOS USB COM to simulate RS-232 standard interface Select USB-COM-STD a. Download the correct USB COM driver from www.datalogic.com Quick Reference Guide...
  • Page 26 Selecting the Interface Type IBM-46xx Port 5B reader interface Select IBM-P5B IBM-46xx Port 9B reader interface Select IBM-P9B USB-OEM USB-OEM (can be used for OPOS/UPOS/JavaPOS) Select USB-OEM Gryphon™ I GBT4400...
  • Page 27: Keyboard Interface

    Selecting the Interface Type Keyboard Interface Use the programming bar codes to select options for USB Keyboard and Wedge Interfaces. KEYBOARD AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/ Standard Key Encoding Select KBD-AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD-AT-NK AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 &...
  • Page 28 Selecting the Interface Type KEYBOARD (continued) PC/XT w/Standard Key Encoding Select KBD-XT Keyboard Wedge for IBM Terminal 3153 Select KBD-IBM-3153 Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard Select KBD-IBM-M Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard Select KBD-IBM-MB USB Keyboard with alternate key encoding...
  • Page 29: Scancode Tables

    Selecting the Interface Type KEYBOARD (continued) Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx Select KBD-DIG-VT USB Keyboard with standard key encoding Select USB Keyboard WAND EMULATION Wand Emulation Select WAND Scancode Tables Reference the Gryphon™ PRG for information about control character emulation which applies to keyboard interfaces.
  • Page 30 Selecting the Interface Type COUNTRY MODE ENTER/EXIT PROGRAMMING MODE Country Mode = U.S. Country Mode = Belgium Country Mode = Britain Country Mode = Croatia* *Supports only the interfaces listed in the Country Mode feature description Gryphon™ I GBT4400...
  • Page 31 Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Czech* Country Mode = Denmark* Country Mode = France Country Mode = Germany Country Mode = Hungary* Country Mode = Italy *Supports only the interfaces listed in the Country Mode feature description Quick Reference Guide...
  • Page 32 Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Japanese 106-key* Country Mode = Norway* Country Mode = Poland* Country Mode = Portugal* Country Mode = Romania* Country Mode = Spain *Supports only the interfaces listed in the Country Mode feature description Gryphon™...
  • Page 33 Selecting the Interface Type COUNTRY MODE (continued) Country Mode = Sweden Country Mode = Slovakia* Country Mode = Switzerland* *Supports only the interfaces listed in the Country Mode feature description Quick Reference Guide...
  • Page 34: Caps Lock State

    Selecting the Interface Type Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is se- lected. ENTER/EXIT PROGRAMMING MODE Caps Lock State = Caps Lock OFF Caps Lock State = Caps Lock ON Caps Lock State = AUTO Caps Lock Enable...
  • Page 35: Numlock

    Selecting the Interface Type Numlock This option specifies the setting of the Numbers Lock (Num- lock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard. ENTER/EXIT PROGRAMMING MODE Numlock = Numlock key unchanged Numlock = Numlock key toggled Quick Reference Guide...
  • Page 36: Programming

    Programming Programming The reader is factory-configured with a set of standard default features. After scanning the interface bar code from the Inter- faces section, select other options and customize your reader through use of the programming bar codes available in the Product Reference Guide (PRG).
  • Page 37: Reading Parameters

    Reading Parameters Reading Parameters Point the reader at the target and pull the trigger to enable the aiming system and the illuminator (red beam) to capture and decode the image. The aiming system will briefly switch off during the acquisition time and if no code is decoded will switch on again before the next acquisition.
  • Page 38: Good Read Green Spot Duration

    Reading Parameters Good Read Green Spot Duration Successful reading can be signaled by a good read green spot. Use the bar codes below to specify the duration of the good read pointer beam after a good read. ENTER/EXIT PROGRAMMING MODE Green Spot Duration = Disable (Green Spot is Off) ♦...
  • Page 39: Scan Modes

    Scan Modes Scan Modes The imager can operate in one of several scanning modes. When the trigger is pulled, scanning is activat- Trigger Single — ed until one of the following occurs: - a programmable duration has elapsed - a label has been read - the trigger is released This mode is associated with typical handheld reader opera- tion.
  • Page 40 Scan Modes SCAN MODE ENTER/EXIT PROGRAMMING MODE ♦ Scan Mode = Trigger Single Scan Mode = Trigger Hold Multiple Scan Mode = Trigger Pulse Multiple Scan Mode = Flashing Scan Mode = Always On Scan Mode = Stand Mode Gryphon™ I GBT4400...
  • Page 41: Pick Mode

    Scan Modes Pick Mode Pick Mode is a Decoding and Transmission process where bar codes that are not within the configurable distance from the center of the aiming pattern are not acknowledged or trans- mitted to the host. It is active only while the scanner is in Trig- ger Single mode.
  • Page 42: Technical Specifications

    Technical Specifications Technical Specifications The following table contains Physical and Performance Char- acteristics, User Environment and Regulatory information. Physical Characteristics White/Gray Color Black/Gray Height 7.1”/181 mm Dimensions Length 3.9”/100 mm Width 2.8”/71 mm Approximately Weight (without cable) 8.7 ounces/246 g (reader) 8.7 ounces/246 g (base charger) Electrical Characteristics Battery Type...
  • Page 43 Technical Specifications Depth of Field (Typical) Symbology 5mil: 1.6” -7.5” (4.0 -19cm) 3mil: 0.9” - 3.6” (2.4 - 9.1cm) Code 39 10mil: 0.4” - 11.8” (1.0 - 30cm) 5 mil: 0.3” - 4.5” (0.8 -11.3cm) 20mil: up to 17.7” (up to 45cm) 7.5mil: 0.5”...
  • Page 44 PPT; Code 32 (Italian Pharmacode 39); Code 128; Code 128 ISBT; Interleaved 2 of 5; Standard 2 of 5; Interleaved 2 of 5 CIP (HR); Industrial 2 of 5; Discrete 2 of 5; Datalogic 2 of 5 (China Post Code/Chinese 2 of 5); IATA 2of5 Air cargo code; Code 11; Codabar; Codabar (NW7); ABC Cod- abar;...
  • Page 45 Technical Specifications Scanner withstands 18 drops from 1.8 meters Drop Specifications (5.9 feet) to concrete Ambient Light Immunity Up to 100,000 Lux Contaminants Spray/rain IEC 529-IP52 (scanner only) Dust/particulates ESD Level 16 KV Regulatory Electrical Safety UL 60950, CSA C22.2 No. 60950, IEC 60950 Europe - CE;...
  • Page 46: Led And Beeper Indications

    LED and Beeper Indications LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional“Green Spot” also performs useful functions. The following tables list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and so may or may not be turned on.
  • Page 47 LED and Beeper Indications Indication Description Beeper Upon successful read of a label, the soft- Green Spot ware shall turn the flashes green spot on for the momentarily time specified by the configured value. Blue light flashes Image When ready to cap- 2 times when Capture ture image...
  • Page 48: Programming Mode

    LED and Beeper Indications Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. INDICATION DESCRIPTION BEEPER A valid programming LED blinks Reader sounds Label Programming label has been continu- four low fre- Mode Entry scanned.
  • Page 49: Error Codes

    Error Codes Error Codes Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is reset, the sequence will be repeated. The following table de- scribes the LED flashes/beep codes associated with an error found.
  • Page 50: Base Station Indications

    Base Station Indications Base Station Indications Indication LEDS Power-up Complete Yellow LED on Reader Disabled by the HOST or the communication with HOST is Yellow LED blinking ~1Hz not established Data/labels are transmitted to the Yellow LEDs turned off HOST for 100mSec Programming Mode Yellow LED blinks quickly...
  • Page 51: Statement Of Agency Compliance

    Any changes or modifications to equipment, not expressly ap- proved by Datalogic could void the user's authority to operate the equipment. Statement of Agency Compliance This device complies with part 15 of the FCC Rules.
  • Page 52: Fcc Rf Radiation Exposure Statement

    Statement of Agency Compliance FCC RF Radiation Exposure Statement Exposure to Radio-Frequency Radiation CAUTION To comply with FCC RF exposure compliance requirements, for mobile configurations, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons.
  • Page 53 Statement of Agency Compliance Anatel Statement “Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resolução 242/2000, e atende aos requisitos técnicos aplicados. ” Para malores informações, consulte o site da ANATEL www.anatel.gov.br Modelo: GBT4400 Agência Nacional de Telecomunicações 0105-11-4727 (01)07898916345857 “Este equipamento opera em caráter secundário, isto é, não...
  • Page 54 Statement of Agency Compliance China RoHS Table of Restricted Elements (GBT4400 Kits) Gryphon™ I GBT4400...
  • Page 55: Imager Labeling

    Statement of Agency Compliance Imager Labeling Sample labels are shown for placement purposes only. Please view the labels on your product for actual details, as they may vary from those depicted. Scanner Regulatory Label Base Station Label 239045 PATENTS PENDING Aiming System ™...
  • Page 56 Statement of Agency Compliance LA LUCE LE RAYON DIE LASER-STRAH- LASER È VISI- LASER EST VISI- LUNG IST FÜR DAS A LUZ LÁSER ES BILE BLE À L'OEIL MENSCHLICHE VISIBLE AL OJO ALL'OCCHIO NU ET IL EST AUGE SICHTBAR HUMANO Y ES UMANO E ÉMIS PAR LA UND WIRD AM...
  • Page 57 Statement of Agency Compliance The product utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known bio- logical damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid allowing the laser beam to hit the eye of an observer, even through re- flective surfaces such as mirrors, etc.
  • Page 58 Statement of Agency Compliance Es ist nicht notwendig, das Gerät wegen Betrieb oder Installa- tions-, und Wartungs-Arbeiten zu öffnen. Jegliche Änderungen am Gerät sowie Vorgehens- weisen, die nicht in dieser Betriebsanleitung besch- reiben werden, können ein gefährliches Laserlicht verursachen. ACHTUNG Der Produkt benutzt eine Laserdiode.
  • Page 59 Statement of Agency Compliance ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se re- fieren al uso correcto del terminal. NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de se- guridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1.
  • Page 60: Weee Statement

    Sie auf der Webseite www.datalogic.com. Spanish Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y electrónico (WEEE), visite la página Web www.datalogic.com. Portuguese Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e Eletrônicos (WEEE -Waste Electrical and Electronic Equipment), consultar o site web...
  • Page 61: Datalogic Adc Limited Factory Warranty

    Datalogic ADC (“Datalogic”) hardware products are warranted against defects in material and workmanship under nor- mal and proper use. The liability of Datalogic under this warranty is lim- ited to furnishing the labor and parts necessary to remedy any defect covered by this warranty and restore the product to its normal operating condition.
  • Page 62: Warranty Exclusions

    Risk of Loss Customer shall bear risk of loss or damage for product in transit to Dat- alogic. Datalogic shall assume risk of loss or damage for product in Dat- alogic’s possession. In the absence of specific written instructions for the...
  • Page 63: Ergonomic Recommendations

    Ergonomic Recommendations Ergonomic Recommendations In order to avoid or minimize the potential risk of ergo- nomic injury follow the recommendations below. Con- sult with your local Health & Safety Manager to ensure CAUTION that you are adhering to your company’s safety pro- grams to prevent employee injury.
  • Page 64: Services And Support

    Services and Support Services and Support Datalogic provides several services as well as technical support through www.datalogic.com its website. Log on to and click on the links in- dicated for further information. Products Search through the links to arrive at your product page where you can...
  • Page 65 Services and Support NOTES Quick Reference Guide...
  • Page 66 Services and Support NOTES Gryphon™ I GBT4400...
  • Page 67: Declaration Of Conformity

    La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva di Datalogic ADC Srl per: This Declaration of Conformity is issued under the sole responsibility of Datalogic ADC Srl for: Cette déclaration de conformité est établie sous la seule responsabilité de Datalogic Srl pour: Diese Konformitätserklärung wird unter der alleinigen Verantwortung des Datalogic ADC Srl...
  • Page 68 ©2010-2014 Datalogic ADC, Inc. • All rights reserved. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. Datalogic ADC, Inc. 959 Terry Street Eugene |OR 97402 Telephone: (1) 541-683-5700...

Table of Contents