Reset Enabled; Enrollment Of The Control Panel To A Uc-2Xx Or To A Master Control Panel; No Code Requested For; Partial (Home) Arming With (F2) (Non Split Control Panel) - jablotron MAESTRO JA-65 Installation Manual

Alarm system
Hide thumbs Also See for MAESTRO JA-65:
Table of Contents

Advertisement

options:
2 7 1
2 7 0
Factory default setting: checking disabled
Note: in some locations with a strong radio interference (near radar, TV or radio station etc.) the communication can be jammed periodically. The control
panel can detect such a strong interference as a temporary loss of communication with an item. Even in this case, the system is usually able to work
without any problems, because all important data is repeated, but the communication check should not be used.

12.9. Reset enabled

The factory default reset (see 17.) can be disabled. This way no unauthorized future programming of the control panel will
be possible.
options:
2 8 1
2 8 0
Factory default setting: reset enabled
Note: if the Master or Service code is forgotten when the reset is disabled, the reset of the control panel will be possible only by the manufacturer.
12.10. Enrollment of the control panel to a UC-2xx or to a master control panel sequence: 2 9 9
The control panel can send wireless data to output modules UC-2xx (see section 25.) and it can also work as a
subsystem of another JA-65 or JA-60 control panel.
Enter the enrolling mode of the UC receiving device and then enter 299 and the control panel will generate the
enrollment signal.
If you want to enroll a subsystem to your control panel, enter the enrolling mode on the MASTER control panel (see
12.1.) and then enter sequence 299 in the programming mode of the sub control panel.
If the system is split, the sub control panel enrolls to the common shared section.

12.11 No code requested for

If this parameter is enabled, no code is requested for functions F1, F2, F3, F4 and F9 (or the
keypad). When this parameter is disabled, these functions (keys) can be used only when followed by a code (Master or
User) – see the following table:
function / setting
arming
partial arming
door opening
memory reading
message listening
„code" = Master or User
Factory default setting: no code requested
Note: this feature is also selectable on the JA-60D wireless keypad and it is independent from the control panel setting.
12.12. Partial (Home) arming with
In partial arming, the control panel reacts only to detectors addressed to section A (see 12.2 and 12.22) and it ignores
the triggering of detectors in section B or C (except smoke and gas detectors). Partial arming can be disabled with this
sequence.
options:
3 1 1
3 1 0
Factory default setting: partial arming enabled
Alarm system JA-65 MAESTRO
checking enabled
checking disabled
reset enabled
reset disabled
,
,
300
„code"
F 2 „code"
F 3 „code"
F 4 „code"
F 9 „code"
partial arming enabled
partial arming disabled
(F1, F2, F3), F4 & F9
,
301
F 1
F 2
F 3
F 4
F 9
(F2) (non split control panel)
- 12 -
sequence: 2 8 x
sequence: 3 0 x
,
,
keys on the
,
sequence: 3 1 x
MFM51202