2. OPERATING THE JABLOTRON 100 SYSTEM

2.2.1.1 ALARM SETTING

1. Authorize using the keypad.
Sections which can be controlled
are lit up and the backlit indication
button will start flashing green.
While setting the alarm, if any detector is triggered (e.g. an open window) the system will react (based on the
system configuration) in one of the following ways:
Detectors will guard automatically after they switch to standby mode (default setting)
a
The system will optically indicate triggered detectors with a segment flashing red for 8 seconds and the
a
system will set automatically once this period has expired.
Setting the section with triggered detectors is also possible by pressing the segment button on the right
a
side repeatedly. This way a user confirms an intention to set the section with a triggered detector (e.g. an
opened window). Otherwise the system will not set.
A triggered detector will prevent the section from being Set. This status is optically indicated by a fla
a
shing red segment button. The detector preventing setting will be shown on the keypad's display menu.
Unsuccessful setting is indicated by yellow a flashing indication button.
Consult the installation with a service technician in order to program the desired behaviour of the system.

2.2.1.2 ALARM UNSETTING

1. When you enter the building
(triggering a detector with a
"Delayed zone" reaction), the
system starts indicating entrance
delay with a continuous tone and
flashing a green segment button
of the section in which the delayed
entrance has been triggered.
Note: If the "Unset section by authorization only during entrance delay" parameter is enabled, then mere
authorization will unset such section where the entrance delayed has been triggered.
Consult the installation with a service technician in order to program the desired behaviour of the system.
2. Press the right button
(the one which isn't lit up) to set
a particular section. It is possible
to set more sections
subsequently. The delay between
sections selection must not be
longer than 2 seconds.
Authorize yourself using the
keypad – the green indication light
of the authorization panel starts
flashing.
2. Press the left segment button
of the sections you want to unset.
3. The command is executed and
the keypad acoustically indicates
the exit delay. The section is set
now, only the detectors with a
"Delayed Zone" reaction provide
time to leave the guarded area
during the Exit delay. The segment
button of the set section turns red.
3. The command is executed
and the segment buttons turn
green to indicate an unset section.
9