8.2. Enrollment (teaching) of wireless items

As a maximum 16 detectors and 8 controllers (remote controls & keypads) can be enrolled to the control panel. A wire-
less siren and an additional JA-6x control panel (subsystem) can be enrolled as well.
• press key 1 (while „P" is displayed) to enter the enrolling mode. The control panel will display the next free position to
enroll a detector.
• Use key 1 and 6 to scroll (up and down) all control panel positions – 1 to 16 (detectors) – c1 to c8 (controllers & key-
pads) – A (wireless siren) – J (sub control panel JA-60, 65). The display shows the position number while the Battery
LED indicates if the position is occupied (If the Battery LED is illuminated, it indicates that position is occupied).
• Detectors and keypads are automatically enrolled when their power is switched on (batteries are installed). A remote
control is enrolled only after both of its buttons are simultaneously pressed and held for 3 seconds. A subsystem con-
trol panel will enroll after sequence 299 is entered while it is in its programming mode. The system will not allow en-
rollment of an item into a non-corresponding position (a detector can not be enrolled into a controller position etc.). If
you try to enroll an item into an incorrect position, the control panel will automatically select a suitable position.
• Control panel confirms enrollment with a „beep" (press F to select a louder "beep" sound). The LED display will
show the number of the enrolled item for 2 seconds and then it will display the number of the next free position.
• To change the position of an enrolled item is simple. Enroll it to the new selected position (the item will „move"). If
you enroll an item to an occupied position, the former item will be deleted and only the new enrollment is valid. Only
one item (detector, controller etc.) can be stored to each position.
• Erase an enrolled item the following way: in the enrolling mode select the corresponding position and then press
and hold key 2 for two seconds. The item will be erased (confirmed with a long beep). If you press and hold key 3, all
enrolled controllers (remote controls and keypads) will be erased. Pressing and holding key 4 will erase all enrolled
items (detectors, controllers, siren and the sub system).
• The JA-60A wireless siren will generate an enrollment signal when its power is switched on (it will enroll to posi-
tion A). If you need to enroll a siren which is already powered and it is not possible to easily switch off its power, you
can enroll it the following way: enter the enrolling mode and then enter the 6 digit siren production code (printed in the
siren's manual). The control panel will "request" the siren to send its enrollment signal. The siren will send the signal
only if it has no current communication with any other control panel (This protects you from enrolling your neighbor's
siren). Enrollment is completed about five seconds after the code is entered.
Note: if an item was not enrolled after its batteries were installed, it is because the control panel recognized its radio sig-
nal as a weak one. Items are only enrolled if their radio signal has a level which guarantees reliable communication.
Check the detector's batteries and try to enroll the problematic sensor once more. If it is not accepted by the control
panel, you should change the location of the item. All items should be located 1 m or more from the control panel.

8.3. Exit delay

To change the duration of the exit delay enter
20x
(where x represents time in seconds x10). The delay can be selected from 10 to 90 seconds.
Example: to select an Exit delay duration of 20 seconds, enter 202
Factory default setting is 30 seconds

8.4. Entrance delay

To change duration of the entrance delay enter:
21x (where x represents time in seconds x10). The delay can be selected from 10 to 90 seconds.
Example: To select entrance delay duration of 40 seconds, enter 214
Factory default setting: 30 seconds

8.5. Alarm duration

The alarm duration can be selected from 1 to 8 or 15 minutes (or 10 seconds) entering 22x (where x represents time in
minutes, for x=0 the duration will be 10 seconds, for x=9 the duration will be 15 minutes).
Example: to select an alarm duration of 5 minutes, enter 225
Factory default setting is 4 minutes

8.6. PgX and PgY outputs function

The control panel outputs PgX and PgY can have different functions, depending on parameter x in the corresponding
sequence:
2 3 x – determines triggering of PgX
2 4 x – determines triggering of PgY
Alarm system JA-60 "COMFORT"
- 13 -
enter: 1
sequence: 2 0 x
sequence: 2 1 x
sequence: 2 2 x
sequences: 2 3 x & 2 4 x