Alarm Setting; Alarm Unsetting - jablotron 100 User Manual

Hide thumbs Also See for 100:
Table of Contents

Advertisement

8
2. OPERATING THE JABLOTRON 100 SYSTEM

2.1.1 ALARM SETTING

1. Authorize using the keypad. Sections
which can be controlled are lit up and the
backlit indication button will start fl ashing
green.
While setting the alarm, if any detector is triggered (e.g. an open window) the system will react (based on
the system confi guration) in one of the following ways:
a
Detectors will guard automatically after they switch to standby mode (default setting)
a
The system will optically indicate triggered detectors with a segment fl ashing red for 8 seconds and the
system will set automatically once this period has expired.
a
Setting the section with triggered detectors is also possible by pressing the segment button on the right
side repeatedly. This way a user confi rms an intention to set the section with a triggered detector (e.g. an
opened window). Otherwise the system won't set.
a
A triggered detector will prevent the section from being Set. This status is optically indicated by a fl a
shing red segment button. The detector preventing setting will be shown on the keypad's display menu.
Unsuccessful setting is indicated by yellow a fl ashing indication button.
Consult the installation with a service technician in order to program the desired behaviour of the system.

2.1.2 ALARM UNSETTING

1. When you enter the building (trigge-
ring a detector with a "Delayed zone"
reaction), the system starts indicating
entrance delay with a continuous tone
and fl ashing a green segment button of
the section in which the delayed entrance
has been triggered.
Note: If the "Unset section by authorization only during entrance delay" parameter is enabled, then mere
authorization will unset such section where the entrance delayed has been triggered.
Consult the installation with a service technician in order to program the desired behaviour of the system.
2. Press the right button (the one which
isn't lit up) to set a particular section.
It's possible to set more sections
subsequently. The delay between secti-
ons selection must not be longer than
2 seconds.
Authorize yourself using the keypad –
the green indication light of the authoriza-
tion panel starts fl ashing.
2.
Press the left segment button of the
sections you want to unset.
3. The command is executed and the
keypad acoustically indicates the exit
delay. The section is set now, only the
detectors with a "Delayed Zone" reaction
provide time to leave the guarded area
during the Exit delay. The segment button
of the set section turns red.
3. The command is executed and the
segment buttons turn green to indicate
an unset section.