4.2 External antenna use

An optional external antenna, model AN-01, can be used with the 65R module. This antenna has a connector, which fits
the connector on the 65R module. If you use the external antenna, the rubber antenna should not be installed. The AN-01
antenna has a small plastic ring on its end, used to hang it from the wall. Its active part (from the plastic ring to the coil)
should be installed vertically and should not be obstructed by any large metal object. The antenna can be located behind
furniture, etc.

5. Connection of a telephone line to the JA-65X module

If the JA-65X module is installed, the control panel can communicate with a
Monitoring Station, send voice messages and dial a numeric Pager as well as
communicate with a remote PC. A standard analog telephone line (type TNV 1-
3) must be connected to the 65X module for these functions.
• Use the provided telephone cable to connect the telephone line to the IN
jack in the 65X module (see diagram )
• Connect a telephone, fax or other phone operated device to the OUT jack,
marked with a phone symbol
• When the control panel is in normal stand by mode, the phone line and any
attached device will operate as normal
Note: The communicator must be plugged directly to a telephone line socket.
All other devices (telephone, facsimile machine, modem etc.) should be
connected to the communicator output.

6. Connectors and terminals of the main board

In addition to the interface module connectors (K1, K2 and K3) the main board has the following connectors:
K5 - power supply connector: the cable from the power unit is connected to this . By disconnecting this cable you
completely power-down the system (for example, when you perform a factory default reset).
K4, K6 - digital data jacks for the JA-60E keypad(s) and/or for a PC interface cable. Up to five JA-60E keypads can
be connected to a JA-65 and the maximum length of the cable can be 500 meters. We recommend use of a CT-04 cable
and RJ-44 (Jablotron) crimping connectors to make the keypad cables. The digital data is also available on the terminals:
see the following description.
1,2,3,4 - digital data terminals (see K4, K6) provide an option to use standard cable for the wiring of JA-60E keypads. The
keypads are also equipped with both jacks and terminals.
The following terminals are on the bottom side of the main board:
TMP
a pair of terminals to connect the tamper switch of an external device (for example: a wire operated outdoor siren,
OS-300). In normal use, these terminals should be connected together via a 10k resistor. Triggering of this loop
has the same effect as control panel tampering (a change of ±30% or more of the End Of Line resistor will trigger the
input).
PGX
is an output (transistor switching to GND, max. 12V, 100mA). The function of this output is determined by the setting in
the programming mode (see 12.5). The control panel also wirelessly transmits the PGX signal and unit UC-216 or
UC-222 can be used as a remote output of this signal.
PGY
is an output (transistor switching to GND, max. 12V, 100mA). The function of this output is determined by the setting in
the programming mode (see 12.5). The control panel also wirelessly transmits the PGY signal and unit UC-216 can
be used as a remote output of this signal.
C
is a common contact of the alarm output relay, max. load 60V / 1A. The relay is turned on during any alarm of the
control panel.
NC
is a normally closed contact of the alarm output relay.
NO
is a normally open contact of the alarm output relay.
GND
is a common ground terminal of the power output (-). This terminal is also available on 65H modules.
SIR
is an external siren output. In the normal mode it has the +U terminal voltage. In the alarm mode it has a GND terminal
potential. Connect an ordinary external siren to +U and SIR terminals (max. load 1A). A back up siren charging input
should be connected to the GND and the SIR terminals (during an alarm, the charging will temporarily halt). The siren
can also be used for sounding arming and disarming chirps and as an audible indicator while in the testing mode.
+U
is a back up power output for external items (detectors etc.). A positive voltage on this terminal is a duplicate of the
backup battery voltage. The permanent load should not be higher than 1,5 A. This output is fused and supervised by
the control panel. If it is overloaded, a control panel failure will be indicated (fault C). The multiple +U terminals are also