Hard Wired Siren Alarm Enabled; Exit Delay Audible Indication; Partial Arming Exit Delay Audible Indication; Entrance Delay Audible Indication - jablotron MAESTRO JA-65 Installation Manual

Alarm system
Hide thumbs Also See for MAESTRO JA-65:
Table of Contents

Advertisement

12.13. Hard wired siren alarm enabled

The SIR siren output is activated when any alarm is triggered (except silent Panic alarm). The siren indication can be
disabled with this parameter.
options:
3 2 1
3 2 0
Factory default setting: siren enabled

12.14. Exit delay audible indication

The exit delay can be indicated by the „beeping" of the keypad (for the last five seconds, the beeping is faster). The
audible indication can be disabled with this setting.
options:
3 3 1
3 3 0
Factory default setting: indication enabled

12.15. Partial arming exit delay audible indication

Partial arming with
arming can be indicated by the „beeping" of the keypad (for the last five seconds the beeping is faster).
options:
3 4 1
3 4 0
Factory default setting: indication disabled
Note: when this indication is disabled, the confirmation of partial arming and disarming will automatically be silent, regardless of the 36x setting.

12.16. Entrance delay audible indication

The entrance delay can be indicated by a rapid „beeping" of the keypad. This indication can be disabled with this setting.
options:
3 5 1
3 5 0
Factory default setting: indication enabled

12.17. Arming and disarming chirps with hard wired siren

An ordinary siren connected to the control panel SIR output can confirm arming with a loud beep and disarming with two
loud beeps (3 beeps after disarming indicates user information on the LED display).
options:
3 6 1
3 6 0
Factory default setting: siren chirps disabled
Note: setting of chirp sounds is valid even if the siren is disabled for alarms with parameter 320. Partial arming is always silent, if sequence 340 is
selected. Chirp sounds can also be generated with the JA-60A wireless siren (self-contained setting in the wireless siren).
12.18. Siren alarm in Disarm & Partial arming
The SIR output can be disabled for alarms during the Disarm & Partial arming of the control panel (while somebody is
indoors). If the siren output is completely disabled for alarms with parameter 320, this setting has no effect.
options:
3 7 1
3 7 0
Factory default setting: enabled
Alarm system JA-65 MAESTRO
siren enabled
siren disabled
indication enabled
indication disabled
(F2) provides an exit delay for delayed reaction detectors in section A. The exit delay for partial
indication enabled
indication disabled
indication enabled
indication disabled
siren chirps enabled
siren chirps disabled
alarm in disarm & partial arming enabled
alarm in disarm & partial arming disabled
- 13 -
sequence: 3 2 x
sequence: 3 3 x
sequence: 3 4 x
sequence: 3 5 x
sequence: 3 6 x
sequence: 3 7 x
MFM51202

Advertisement

Table of Contents
loading

Table of Contents