Notes:
• If the control panel is not split, this setting has no effect.
• Master code (MC) can not be addressed. If the system is split, the use of MC will arm all sections if no section is armed or it will
disarm all sections if any is armed.
Example: to address user code number 4 to section A enter: 62 04 1
Factory default setting: all user codes (01 - 14) are addressed to section A

12.24. Addressing of wireless controllers to sections

If the control panel is split (see 12.21.) and is equipped with a 65R module, the wireless controllers (RC-11, RC-22 and
JA-60D) can be addressed to A or B section by entering:
63 nns
where: nn = number of the enrolled controller from 01 to 08 (c1 to c8)
s = section: 1 = A, 2 = B
Notes:
• If the control panel is not split, this setting has no effect
• For the JA-60F keypad this setting has no effect (its user codes are determined by 62nns setting)
Example: to address controller number 5 to section A enter: 63 051
Factory default setting: all wireless controllers are addressed to section A

12.25. Automatic arming / disarming setting

The control panel can automatically arm and disarm for a requested period of a day. Up to ten instructions (time & action)
can be programmed in the period of one day by entering:
64 nahhmm
where: n = instruction number from 0 to 9
a = action (see the actions' table)
hh = hours (from 00 to 23)
mm = minutes (from 00 to 59)
Notes:
• If any automatic action is selected, it will be preformed everyday in the programmed time, following the internal control panel clock
(see 12.27.).
• The automatic arming and disarming can be overridden manually anytime (by an user code or a remote control)
• If the control panel is in the requested arming mode before the action time, performance of the programmed action will not change
the arming
Example: to program an automatic complete arming of the system at 21:15 everyday enter: 64 0 1 21 15
Factory default setting: all instructions are set for no action

12.26. New service code setting

The Service Code can be used to enter the programming mode. A new Service Code must be entered twice in the
sequence to avoid an error.
To change the code enter:
Example: to change service code to 1276 enter: 5 1276 1276
Factory default setting: service code is 6060
Alarm system JA-65 MAESTRO
5 nSC nSC
where nSC is your new Service Code (four digits)
- 15 -
sequence: 63 nns
sequence: 64 nahhmm
actions' table
a
no splitting
split system
0
no action
no action
1
arm all
arm all
2
disarm
disarm all
3
partial arming
arm A
4
partial arming
arm B
5
disarm
disarm A
6
disarm
disarm B
sequence: 5 nSC nSC