16.5. Phone number entering

Monitoring station modem phone numbers can be stored by entering the following sequence:
0 6 x x .... x F y
Pause (3 sec.) can be inserted into the telephone number by entering F0. It is also possible to insert the ∗ ∗ ∗ ∗ tone by F7 or
the # tone by F8 if requested for DTMF dialing.
Example: number 02 123456 as main Monitoring Station number is entered with 06 02 F0 123456 F1.
Phone number erasing
0 6 F 0 F y
Note: Changing of a phone number erases the internal communicator's memory of non reported events and sends a „Reset" reporting
code (051) to the Monitoring Station.
Factory setting: both numbers are erased

16.6. Digital communicator reset

By entering this sequence the factory default settings of all parameters are restored. All phone numbers, reporting codes,
account codes etc. are erased. This reset doesn't effect the voice dialer's settings. The reset sequence is:
0 9 6060
Note: All communicator settings are normally stored in non-volatile memory and remain unchanged even after switching off the power
supply.

17. Control panel factory default reset

If you forgot the control panel codes or you have a control panel which is currently not under factory default setting, perform the
following procedure:
disconnect the power unit cable from the K5 connector on the main board of the control panel
connect the RESET jumper on the main board
reconnect the power cable to the K5 connector, "-" will be displayed on the keypad
within 1 minute enter 6060 on the keypad
reset is confirmed with "P" (panel is in programming mode)
disconnect the RESET jumper on the main board
Note: this procedure resets the factory default settings (see part 12.). The Master code will be 1234, Service code 6060 and all user
codes, wireless detectors & controllers will be forgotten. All telephone numbers for voice message and Pager dialing will be erased in
the 65X communicator. The reset will not erase event memory and information about the reset will be recorded there.
Warning: if the Master code is forgotten when reset is disabled (with sequence 280), the control panel reset will be possible only by the
manufacturer.
Alarm system JA-65 MAESTRO
xx...x - Monitoring Station phone number (up to 16 digits)
y
is
1 for main phone number memory
2 for back up phone number memory
y
is
1 to erase the main telephone number
2 to erase the back up telephone number