Control Panel Programming - jablotron MAESTRO JA-65 Installation Manual

Alarm system
Hide thumbs Also See for MAESTRO JA-65:
Table of Contents

Advertisement

Switch on the AC power
The keypad will display a "P", confirming that the system is in the programming mode (for system setting, enrollment of
wireless items and for testing).
Note: if „P" is not displayed, the control panel is not in the factory default setting. Perform a Factory default reset. (See section 17).

12. Control panel programming

Functions of the system can be customized. The most convenient programming method is via a connected PC using the Comlink
software (see 19). Programming can also be performed by entering programming sequences from the system keypad while in the
programming mode:
If the control panel is not in the programming mode, open it (entering F 0 SC - SC = Service Code, factory default SC=6060) –
The programming mode will be indicated by a „P" on the LED display. This mode can only be entered when the panel is
disarmed. In this mode, no alarm can be triggered. Detectors and other accessories can be enrolled, the system parameters
can be set up and the system can be tested.
The parameters of the control panel can be set by entering programming sequences from the keypad. Any unfinished
programming sequence can be terminated by pressing the N key.
To exit the programming mode, press the N key („P" will turn off). If any fault is indicated when you try to exit the
programming mode, the control panel will inform you of the problem (see programming sequence 39x for more details).
List of control panel programmable parameters
Function
Enrolling of detectors and controllers
Hard-wired zone input setting
Exit / Entrance delay
Alarm duration
Function of PgX output
Function of PgY output
Voice m. & tel. Numbers editable in the user mode
Radio signal jamming regular testing
Regular communication check enabled
RESET enabled
Control panel teaching to a UC-2xx, subsystem,...
No code requested (effects
Partial (Home) arming enabled (
Siren alarm enabled
Exit delay audible indication enabled
Partial arming exit delay audible indication
Entrance delay audible indication enabled
Arming & disarming chirp sounds enabled
Siren in Disarm & Partial arming enabled
Wireless siren alarm enabled
Indication of system problems when arming
Split control panel (A, B & C sections)
Addressing of wireless detectors to sections
Addressing of user codes to sections
Addressing of wireless controllers to sections
Automatic arming/disarming setting
New Service Code setting
Real time and date setting
Alarm system JA-65 MAESTRO
,
,
, F4 & F9)
)
64nahhmm
5
sequence
options
1& 7 scroll, 2 erase pos., 4 all
1
nn– zone n., x– triggering,
60 nn xyz
y– reaction, s- section
x = 1 to 9 (x 10sec.)
21x
x = 1 to 8 (min.), 0=10s,
22x
9=15min
x = 0 to 7 (0-Chime, 1-Fire, 2-
23x
Arm, 3-Panik, 4-Alarm, 5-Door,
6-Home, 7-No AC
x = 0 to 7 (0-Chime, 1-Fire, 2-
24x
Arm, 3-Panik, 4-Alarm, 5-Door,
6-Home, 7-No AC
251 = YES
25x
261 = YES
26x
271 = YES
27x
28x
281 = YES
will send enrolling signal
299
301 = YES
30x
311 = YES
31x
321 = YES
32x
331 = YES
33x
341 = YES
34x
351 = YES
35x
361 = YES
36x
371 = YES
37x
381 = YES
38x
391 = YES
39x
6901 = YES
690x
nn– zone n., s- section
61 nns
nn– code n., s- section
62 nns
nn– controller n., s- section
63 nns
n- 0-9, a-action #, hh-hours,
mm-min.
nSC = new Service Code
nSC nSC
4 hh mm DD MM RR
- 9 -
factory
d.
-
w. R module only
all off
w. H module only
30sec.
4min.
Chime
split system has
different setting
Arm
split system has
different setting
250 = NO
w. X module only
NO
260 = NO
NO
w. R module only
270 = NO
NE
w. R module only
YES
280 = NO
w. R module only
300 = NO
YES
310 = NO
YES
320 = NO
YES
330 = NO
YES
340 = NO
NO
350 = NO
YES
360 = NO
NO
370 = NO
YES
w. R module only
380 = NO
YES
390 = NO
NO
6900 = N0
NO
1-10 A
w. R module only
all A
only when split
all A
split & R module
all off
split & partial
arming see 12.21
6060
enter code twice
00 00 01 01 00
note
MFM51202