25. Control panel specifications:

Electrical
Power
Backup battery
Backup power output for wired items 13VDC, max. 1.5A, supervised
Hard-wired inputs
Zone input triggering
Zone reaction
Wireless communication
Working frequency
Keypads
Access codes
Wired outputs
Wireless outputs
Events memory
Telephone communicator
Monitoring station formats
Environmental
Operating temperature
Operating humidity
Working environment
Electronic design
Design
Electrostatic discharge
RF immunity
Physical
Housing
metal box with built-in electronic power supply
Dimensions
295 x 280 x 90mm
Shipping weight
2.72kg
Color
white or light gray
Standards
Complies with: EN 50131-1 (Grade 2), EN 50131-6, EN 300220, ETS 300 683, EN 50136, ETS 300001, TBR 21
Alarm system JA-65 MAESTRO
110-230 VAC, (built in electronic power supply), supervised
12 V, from 1.3 to 7 Ah (external up to 40 Ah), supervised, not included
module 65H: 8 input zones, up to two 65H modules can be used (16 zones)
selectable: NC, End Of Line resistor or Double End Of Line resistor
selectable: instant, delayed, panic, fire, 24 hour, next delayed
module 65R: up to 16 detectors (JA-60), 8 controllers, 1 outdoor siren JA-60A
433.92 MHz; digital hopping code; supervised communication
max. 5 wired JA-60E keypads, max. 8 JA-60F wireless keypads or RC-11 or
JA-60D remote controllers
master code and 14 user codes. When system is split, codes, detectors and
remote controls can be addressed to particular sectors
Alarm relay dry contacts 1A/60V; programmable outputs PgX & PgY (Chime,
Fire, Arm, Panic, Alarm, Door, Home, AC failure), siren output (12 V, 1 A)
module 65R transmits signals for siren and PgX, PgY data for UC-2xx receivers
127 most recent events including date, time and detailed specification
module 65X: digital communication to a monitoring station, Pager dialing, 2
voice messages, modem communication with a remote PC (ComLink SW + JA-
60U modem), remote keypad access with JA-60E and JA-60U
Contact ID, Ademco, Telemax, Franklin, Radionics, SurGard, DTMF2300, (198
reports codes)
-10°C to 40° C
max 80 %
indoor use (class II, EN 50131-1)
SMT; modular system (radio module 65R, hardwired zones module 65H, telephone communicator module
65X); full supervision; monitoring of RF jamming
8 kV
30 V / m