1. Architecture of the control panel

The JA-65 "Maestro" is a fully programmable control panel with building block architecture. This allows the JA-65 to be
tailored to particular installation requirements. The Maestro can operate as a wireless, wired or combined system.
The JA-65K metal box has a built in electronic power supply. There is space for a 12V, 7Ah back up battery. The 16
zone control panel's main board is installed in the internal platform. The main board does not have any physical zone
inputs. This allows you to co figurate the control panel by using the following modules:
Radio communicating module JA-65R can enroll wireless items (JA-60): up to 16 detectors, up to 8 controllers
(remote controls or wireless keypads), a JA-60A wireless siren and UC family wireless output modules.
Hard-wired input module JA-65H has 8 input loops with programmable triggering (NC, balanced or double
balanced) and programmable reactions. Up to two JA-65H hard-wired input modules can be used in the control
panel.
Telephone communicator JA-65X can communicate with a Monitoring Station, send voice messages and dial a
numeric Pager. It can also communicate with a remote PC (using ComLink SW and a JA-60U modem).
Operation and programming is possible via the JA-60E keypad (or by its wireless option, JA-60F). The control
panel can also be operated by an RC-11 or RC-22 remote control or by a JA-60D wireless keypad. Operation and
programming is also possible via a PC using ComLink SW.
This allows the JA-65 to operate as a wireless (16 detectors), wired (8 or 16 inputs) or combined system. An additional
JA-60 or JA-65 subsystem control panel can expand the system. The control panel can be split in to two independent
sections with a shared common area.