8. Wiring of the JA-60 keypad(s)

The system can be programmed and operated by JA-60E keypad(s). As a maximum, 5 keypads can be wired to the
control panel. The keypads can either be wired by cables equipped with modular jacks to connectors K4 and K5 or by
standard cables to terminals 1,2.3 & 4 on the main control panel board. The same numbered terminals (pins in the
connectors) must be linked together. It is possible to combine arbitrary wiring with modular connectors and ordinary
cables - see diagram.
When a control panel has a JA-65R radio communicating module installed, it can also be operated and programmed
via JA-60F wireless keypad(s) asunder this situation, a minimum of one JA-60E keypad should be connected to the
control panel. With a 65R module, the system can also be operated by remote controls RC-11 & RC-22, as well as by a
JA-60D wireless keypad. The control panel can have up to 8 wireless controllers.
It is also possible to operate and program the JA-65 system via a connected PC with SW ComLink. The PC can be
connected locally with a PC-60A interface cable or remotely, using a JA-60U modem (see section 19 and 20).

9. Installation of wireless items

If the control panel is equipped with a JA-65R module, it can work with all types of JA-60 wireless items and wireless UC
output modules (see brief overview of items in section 25.1).
Detectors - one wireless JA-60 detector can be enrolled to each control panel zone (i.e. up to 16 detector)
Keypads and remote controls - up to 8 wireless controllers can be enrolled to the control panel (JA-60F and
JA-60D keypads, RC-11 and RC-22 remote controls)
JA-60A Wireless siren - only one can be enrolled to a control panel
wireless output modules UC-216 and UC-222 have relays, which copy the status of the control panel's
programmable outputs PgX and Pg Y. An unlimited number of the UC modules can be used with each system.
Follow the particular wireless item manual when installing. After you install the item to desired location, leave it un
powered and without its cover. The method of enrollment is described in section 12.1.

10. Back up battery installation

there is a space for size 12V, 7Ah battery. According to the desired backup period a 12V back up battery from 1.3Ah to
45Ah can be used instead. A battery larger than 7Ah must be installed in an external case and the case must be
equipped with tamper protection.
The control panel recharges and checks the condition of the back up battery. If the system is powered from the battery
for a long time and the battery is nearly discharged, the control panel will first trigger a technical alarm and it will then
disconnect the battery to prevent damage. After the main power is on again, the
battery will be re-connected and will automatically re-charge.
• insert the battery into the control panel
• connect the battery cables (red +, black - )
Warning
- do not make any short connection of the battery terminals!

11. First powering of the control panel

Check that all cables are connected correctly
Alarm system JA-65 MAESTRO
- 8 -
For battery back up time calculation use the
following stand-by consumption rates:
module JA-65R
20mA
module JA-65X
12mA
module JA-65H
15mA
main b. JA-65K
10mA
keypad JA-60E
25mA
MFM51202