Sia Alarm Report Codes; Panel Diagnostic Default Options - Assa Abloy S series Installation & Programming Manual

8/16 zone control communicator
Table of Contents

Advertisement

P195E
17E
Keypad Panic Alarm 4+2 Code -
P195E
18E
Keypad Panic Alarm Restore 4+2 Code -
P195E
19E
Keypad Fire Alarm 4+2 Code -
P195E
20E
Keypad Fire Alarm Restore 4+2 Code -
P195E
21E
Keypad Medical Alarm 4+2 Code -
P195E
22E
Keypad Medical Alarm Restore 4+2 Code -
(SIA event codes are entered by programming a value from the chart on Page 115. For example, to send the SIA "Panic
Alarm" code when a keypad panic is generated you must enter a value of "6" at location P197E1E)
P196E
1-16E
Zone Alarm SIA Reporting Code -
"Panic" Alarm SIA Reporting Code -
P197E
1E
"Fire" Alarm SIA Reporting Code -
P197E
2E
"Medical" Alarm SIA Reporting Code -
P197E
3E

PANEL DIAGNOSTIC DEFAULT OPTIONS

P200E
1E
Display the Panel Software Version Number
P200E
2E
Display Keypad Address Number
P200E
3E
Display Areas Assigned to this Keypad
P200E
4E
Display Active Time Zones
P200E
5E
Display Battery Voltage
P200E
6E
Walk Test Mode
P200E
7E
Write to EEPROM (DTU) Board
P200E
8E
Read from EEPROM (DTU) Board
P200E
9E
Restore User/Installer Codes & Telephone #'s to Default Values
P200E
10E
Restore All Factory Defaults
P200E
11E
Clear Alarm Memory Buffer
P200E
12E
Initiate a Call to the Call-back
Keypad "Panic" Alarm 4+2 Restore Reporting Code
Two digit value from 00-FF
Keypad "Medical" Alarm 4+2 Restore Reporting Code

SIA ALARM REPORT CODES

Restore User & Installer Codes plus Telephone Numbers to Defaults
Keypad "Panic" Alarm 4+2 Reporting Code
Two digit value from 00-FF
Two digit value from 00-FF
Keypad "Fire" Alarm 4+2 Reporting Code
Keypad "Fire" Alarm 4+2 Restore Reporting Code
Two digit value from 00-FF
Keypad "Medical" Alarm 4+2 Reporting Code
Two digit value from 00-FF
Two digit value from 00-FF
Zone Alarm SIA Reporting Codes
(Default value = 1, Alarm Event Code BA)
"Panic" Alarm SIA Reporting Code
(Default value = 6, Panic Alarm Event Code PA)
"Fire" Alarm SIA Reporting Code
(Default value = 4, Fire Alarm Event Code FA)
"Medical" Alarm SIA Reporting Code
(Default value = 5, Medical Alarm Event Code MA)
Display Panel Software Version Number
Display Keypad Address Number
Display Areas Assigned to this Keypad
Read from EEPROM (DTU) Board
110
Display Active Time Zones
Display Battery Voltage
Walk Test Mode
Write to EEPROM (DTU) Board
Restore All Factory Defaults
Clear Alarm Memory Buffer
Initiate a Call to the Call-back
Page 89
Page 89
Page 90
Page 90
Page 90
Page 90
Page 90
Page 90
Page 90
Page 90
Page 90
Page 90
Page 90
Page 90
Page 90
Page 91
Page 91
Page 91
Page 92
Page 92
Page 92
Page 92

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avolution s series

Table of Contents