and closed signals from the reed switch so the zone LED can follow the correct state of the reed switch (ie
open or closed)
Type 31
Visonic Radio PIR - If a Visonic K900 radio PIR is used on the panel selecting Type 31 allows the panel to
correctly recognize the alarm, tamper & battery low signal from this device.
Type 32
Visonic Powercode (unsupervised) - If a Visonic Powercode radio device is used on the panel selecting
Type 32 allows the panel to correctly recognize the alarm, tamper and battery low signal from the device.
The supervisory signal sent by the device is ignored in this mode.
Type 33
Visonic Powercode (supervised) - If the Visonic Powercode range of radio PIR or reed switch are used on
the panel selecting Type 33 allows the panel to correctly recognize the alarm, tamper & battery low signals
from the devices as well as the open/close signal from the reed switch. Selecting this option also starts the
supervise timer (P25E4E). The supervise timer is constantly being reset while valid supervisory signals are
being received from the detector. If no supervise signals are received from the PIR within the supervise
timer value a supervised alarm is generated.
Type 34
Siemens (unsupervised) - If a Siemens radio device is used on the panel selecting Type 34 allows the panel
to correctly recognize the alarm, tamper and battery low signal from the device. The supervisory signal sent
by the device is ignored in this mode.
Type 35
Siemens (supervised) - If the Siemens radio PIR is used on the panel selecting Type 35 enables the same
functions as 34 above plus starts the supervise timer (P25E4E). The supervise timer is constantly being reset
while valid supervisory signals are being received from the detector. If no supervise signals are received from
the PIR within the supervise timer value a supervised alarm is generated.
ARMED ZONE ALARMS to OUTPUT - P128E 1-16E
Option 1 - Output 1
Option 2 - Output 2
Option 3 - Output 3
Option 4 - Output 4
If an Area is Armed and a zone assigned to that Area activates, the zone can trigger selected Outputs for local alarm
signalling. This location assigns Zones to Outputs for alarms that occur when in the Full Armed State.
STAY MODE ZONE ALARMS to OUTPUT - P129E 1-16E
Option 1 - Output 1
Option 2 - Output 2
Option 3 - Output 3
Option 4 - Output 4
If an Area has Stay Mode Armed and a zone assigned to that Area activates, the zone can trigger selected Outputs for local
alarm signalling. This location assigns Zones to Outputs for alarms that occur when Stay Mode is Armed.
24 HOUR ZONE ALARMS to OUTPUT - P130E 1-16E
Option 1 - Output 1
Option 2 - Output 2
Option 3 - Output 3
Option 4 - Output 4
If a zone is programmed as a 24 Hour type and it activates, the zone can trigger selected Outputs for local alarm
signalling. If the zone is a standard 24 hour type (P123E3E) the output will turn for the full reset time, if it is an Auto-reset
type (P123E4E) the output will either turn off when the reset time expires or if the input clears and if it is a Fire type
(P123E5E) the output will pulse at a rate equal to the pulse time for that output.
CHIME ZONE ALARMS to OUTPUT - P131E 1-16E
ARMED ZONE ALARMS to OUTPUT
STAY MODE ZONE ALARMS to OUTPUT
24 HOUR ZONE ALARMS to OUTPUT
CHIME ZONE ALARMS to OUTPUT
Option 5 - Output 5
Option 6 - Output 6
Option 7 - Output 7
Option 8 - Output 8
Option 5 - Output 5
Option 6 - Output 6
Option 7 - Output 7
Option 8 - Output 8
Option 5 - Output 5
Option 6 - Output 6
Option 7 - Output 7
Option 8 - Output 8
72