Keypad Switches; Zones - Assa Abloy S series Installation & Programming Manual

8/16 zone control communicator
Table of Contents

Advertisement

P111E
1-2E
K/S 1 & 2 assigned to Areas A or B -
(1 = K/S # 1) (Default K/S # 1 = 1)
(2 = K/S # 2) (Default K/S # 2 = 2)
P112E
1-2E
K/S 1 & 2 Access & Operational Options
(1 = K/S # 1) (Default = All Off)
(2 = K/S # 2)
P121E
1-16E
Assigning Zones to Areas A or B
(Default = 1)
P122E
1-16E
Programming Zone Options A
(Default Zone 1-4 = 1,6,7,8)
(Default Zone 5-8 = 1,7,8)
(Default Zone 9-16 = 7,8)
P123E
1-16E
Programming Zone Options B
(Default Zone 2, 3 = 1
P124E
1-16E
Programming Zone Options C
(Default = 2)
P125E
1-8E
Programming Zone EOL Options
(Default = 3)
P126E
1-8E
Programming Zone Response
(Default = 15)
KEY SWITCHES
1 = Assigned to Area "A"
2 = Assigned to Area "B"
Key-switch Access & Operational Options
1 = K/S can Arm Area
2 = K/S can arm Stay Mode
3 = K/S can Disarm Area
4 = K/S can disarm Stay Mode
5 = K/S has Security Guard Options
6 = K/S will Arm Latchkey Mode
7 = Key-switch is N/O (If turned off the K/S is N/C)
8 = Key-switch is Momentary (If turned off the K/S is Latching)

ZONES

1 = Assigned to Area "A"
2 = Assigned to Area "B"
1 = Zone is Active
2 = Zone is N/O (Off = N/C)
3 = Spare
4 = Keypad Zone
5 = Zone is a Radio Zone
6 = Zone is a Stay Mode Zone
7 = Zone can be Manually Bypassed
8 = Zone can be Auto-Bypassed
1 = Zone is a Handover Zone
2 = Zone is a Two Trigger Zone
3 = Zone is a 24 Hour Zone
4 = Zone is a 24 Hour Auto-reset Zone
5 = Zone is a 24 Hour Fire Zone
6 = Spare
7 = Zone is a Chime Zone
8 = Zone is a Permanent Chime Zone
1 = Can Arm if Zone is not Ready
2 = Will Send Multiple Reports via Dialler
3 = Sensor-Watch Zone
4 = Zone is on Soak Test
5 = Zone will report to Area B Account Number
6 = Zone will Not Report 24 hour Alarms via Dialler
7 = Pulse Output on Kiss-off Following an alarm
8 = Exit Terminator
Programming Zone EOL (End-of-line) Options
0 = Short Circuit
1 = 1k
2 = 1k5
3 = 2k2
4 = 3k3
5 = 3k9
6 = 4k7
7 = 5k6
8 = 6k8
9 = 10k
10 = 12k
11 = 22k
12 = 2k2 / 4k7
13 = 3k3 / 6k8
14 = 2k2 / 4k7 / 8k2
15 = 4k7 / 8k2
1 to 8 Vibration mode
(Zone EOL-P125E, for Vibration Mode MUST be type 3 only )
1 = highest and 8 is lowest sensitivity level.
102
Key-switch Area Assignment
Programming Zones to Areas
Programming Zone Options A
Programming Zone Options B
Programming Zone Options C
Programming Zone Response
Page 66
Page 67
Page 67
Page 67
Page 68
Page 69
Page 70
Page 70

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avolution s series

Table of Contents