The
'S series' has 9 separate programmable monitored analogue inputs,
8 x
Programmable, multi-state detection inputs which include Zone Doubling options
1 x
Programmable tamper input ( with optional Key-switch functions)
Each input must be terminated with the appropriate value or combination of end-of-line resistors, even if the input is
ZONE INPUTS - Each of the 8 zone inputs can be assigned one of the following End of Line (EOL) configuration options,
Zone EOL Type (P125E)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Type 0 (Short/Loop Circuit)
Type 12-13 (Single Zone with Tamper)
Tamper Resistor
2k2 or 3k3
3k3 (Orange, Orange, Red)
10k (Brown, Black, Orange)
2k2 Tamper, 4k7 Low Zone, 8k2 High Zone
4k7 Low Zone, 8k2 High Zone
n/c
Alarm Contact
n/c or n/o
4k7 or 6k8
unused.
Input Resistor
(Short circuit)
1k (Brown, Black, Red)
1k5 (Brown, Green, Red)
2k2 (Red, Red, Red)
3k9 (Orange, White, Red)
4k7 (Yellow, Violet, Red)
5k6 (Green, Blue, Red)
6k8 (Blue, Grey, Red)
12k (Brown, Red, Orange)
22k (Red, Red, Orange)
2k2 Tamper, 4k7 Zone
3k3 Tamper, 6k8 Zone
Type 1-11 (Single EOL no Tamper)
Type 14 (Zone Doubling with Tamper)
Alarm or Key-sw itch 1 Contact
7
INPUTS
Comments
Loop EOL
Single EOL
Single EOL
Single EOL
Single EOL
Single EOL
Single EOL
Single EOL
Single EOL
Single EOL
Single EOL
Single EOL
Zone & Tamper
Zone & Tamper
Zone Doubling, with Tamper
Zone Doubling, No tamper
n/c
n/o
EOL Resistor
Alarm or Key-sw itch 2 Contact
NC or NO
Tamper
4k7
NC or NO
Tamper
8k2
2k2