P25E
13E
Misc. User Options
(Default = )
P26E
1E
Real Time Hour/Minute -
P26E
2E
Real Time Day of Week -
P26E
3E
Real Time Date/Month/Year -
P26E
4E
Daylight Saving is Active
Saving Time when the panel is installed.
P27E
1E
Daylight Saving Start Sunday -
2E
Daylight Saving End Sunday -
P28E
1E
Daylight Saving Start Month -
2E
Daylight Saving End Month -
P29E
1E
Daylight Saving Start Hour -
2E
Daylight Saving End Hour -
P34E
1-8E
Options "A" for Outputs 1-8
(Default = All Off)
P35E
1-8E
Options "B" for Outputs 1-8
(Default O/P's 1&2 = 7)
(Default O/P's 3-8 = All Off)
P36E
1-8E
Options "C" for Outputs 1-8
(Default = 1)
P37E
1-8E
Options "D" for Outputs 1-8
(Default = All Off)
P38E
1-8E
Output 1-8 ON Delay Time -
P39E
1-8E
Output 1-8 Pulse Time -
Miscellaneous User Options
1 = Code Required to View Memory
2 = Cancel Handover Zone Function in Stay Mode
3 = Output Control from Keypad is Disabled when Armed
4 = Keypad Codes are Disabled During Entry Delay
5 = No Keypad Indications while Armed
6 = Monitored KP Buss Output Board
7 = Enable Keypad Tamper Switch Alarms
8 = Limit Events & Dialler to 3 of any one type
Value 0-2359
Value 1-7 (1=Sunday, 2=Monday ,etc)
Value DDMMYY (eg 020904 = 2nd Sept 2004)
(If LED #1 is On, Daylight Saving is currently active) Turn this bit ON if you are in Daylight
Value 0-5 - Default = 1 (0 = DLS disabled, 5 = last Sunday of Month)
Value 0-5 - Default = 1 (0 = DLS disabled, 5 = last Sunday of Month)
Value 1-12 - Default = 10
Value 1-12 - Default = 4
Value 0-23 - Default = 2
Value 0-23 - Default = 2
OUTPUT
1 = Invert Output
2 = Flash Output
3 = Single Pulse to Output
4 = Lockout Output
5 = DTMF Remote Control can operate Output
6 = User Can operate this Output
7 = "Control" button Can Operate Output
8 = Chime Alarms will Flash this Output (linked to Pulse Timer)
1 = Mains Fail to Output (Operates when P25E6E time expires)
2 = Fuse Failure to Output
3 = Battery Low to output
4 = Telephone Line Failure to Output
5 = Supervised Radio Signal Failure
6 = Sensor-Watch Alarm
7 = System Tamper to Output
8 = Receiver Fail
1 = Walk Test Pulse to Output
2 = Pulse Output every 5 seconds when Disarmed
3 = Pulse Output on Kiss-off Following Arming
4 = Pulse Output on Kiss-off Following a Zone Alarm
5 = Spare
6 = Spare
7 = Spare
8 = Spare
1 = Siren Driver to Output (requires a horn speaker, outputs 1&2)
2 = Output Reset-Chime timers are in minutes (off for seconds-1/10th seconds)
3 = Output 'silenced' for 10 seconds on key-press if alarm
4 = Turn Output OFF during Two Way Voice Mode
5 = Spare
6 = Spare
7 = Spare
8 = Monitored Output (can tell if siren cable is cut, outputs 1&2 only)
0-9999 Seconds (Default = 0 Sec)
0-255;1/10th Sec increments (Default =2 which is 0.2 sec)
96
Setting Real Time Clock
Daylight Saving settings
Programming Output Options "A"
Programming Output Options "B"
Programming Output Options "C"
Programming Output Options "D"
Output ON Delay Time
Output Pulse Time