Armed/Stay Mode Arm Exit Beeps To Output - Assa Abloy S series Installation & Programming Manual

8/16 zone control communicator
Table of Contents

Advertisement

START OF "DTMF ARM/DISARM" STATUS MESSAGES - P64E 1-2E (1 = Area A, 2 = Area B) (0-99)
If a Voice Board is connected to the panel it is possible to dial the panel from a remote telephone and Arm or Disarm
each Area using a 4 digit code with voice prompts provided by the Voice Board to identify what Area you are controlling.
The message programmed at this slot will be the "ARMED" message and the "DISARMED message must always follow
sequentially (eg if area A armed message was at slot 3 the area A disarmed message must be recorded at slot 4). Please
see Voice Board programming on Page 8 for more details.
LED KEYPAD
LED KEYPAD
BUTTON
INDICATION
"BYPASS"
-
"PANIC"
11
"MEMORY"
12
"CONTROL"
13
"ARM"
14
"STAY"
15
ARMED EXIT BEEPS to OUTPUT - P65E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Output 1
Option 2 - Output 2
Option 3 - Output 3
Option 4 - Output 4
Sometimes it can be useful to extend the exit beeps, that occur at a keypad, to be present on an audible device on the
exit path. This option allows the exit beeps during arming to be assigned to any of the 8 outputs. The Pulse time (P39E)
sets the length of each beep.
STAY MODE ARM EXIT BEEPS to OUTPUT - P66E 1-2E (1 = Area A, 2 = Area B)
Option 1 - Output 1
Option 2 - Output 2
Option 3 - Output 3
Option 4 - Output 4
Sometimes it can be useful to extend the exit beeps, that occur at a keypad, to be present on an audible device on the
exit path. This option allows the exit beeps during the arming of stay mode to be assigned to any of the 8 outputs. The
Pulse time (P39E) sets the length of each beep.
AREA DELINQUENCY DELAY - P67E 1-2E (1 = Area A, 2 = Area B) (Value 0-99 Days)
Each Area can have their own Delinquency time. The delinquency time monitors the arm/disarms of each Area. If an Area
has not been armed within the set number of days a delinquency report will be sent. Each time an Area is armed the
delinquency timer is reset. A value of "0" disables the delinquency monitoring.
NOTE: If the default value of "0" is changed at this location (eg a value of 10 is entered meaning 10 days), the next time
the area is armed a delinquency restore message will be sent via the dialler (Event type 454) as a test that the function is
operating.
START OF "DTMF ARM/DISARM" STATUS
ARMED EXIT BEEPS to OUTPUT
LCD KEYPAD
BUTTON
CONTROL & 0
CONTROL & 2
CONTROL & 3
CONTROL & 4
CONTROL & 5
CONTROL & 6
STAY MODE ARM EXIT BEEPS to OUTPUT
LCD KEYPAD
LCD KEYPAD
CID & 4+2
TELEPHONE INDI-
INDICATIONS
CATIONS
-
DELETE #
B
#
C
*
D
-
E
w
F
=
Option 5 - Output 5
Option 6 - Output 6
Option 7 - Output 7
Option 8 - Output 8
Option 5 - Output 5
Option 6 - Output 6
Option 7 - Output 7
Option 8 - Output 8
AREA DELINQUENCY DELAY
57
MESSAGES
CID & 4+2
TELEPHONE NUMBER
SPECIAL
SPECIAL FUNCTION
CHARACTERS
DELETE #
DELETE #
"B"
"#"
"C"
"*"
"D"
"2.5 sec Pause"
"E"
"Wait for 2nd Dial-tone"
"F"
"5 sec Pause"

Hide quick links: